Laserfiche WebLink
_ __-------------� <br /> � O� <br /> O �:.,.. . O <br /> �-���- CITY of ORONO <br /> .� ' ��� -- � <br /> ,�'�► � �I�����,p�� titi M�;�;,� o� <br /> �' '�'��� ;.�, 1�'�'�,G . str�t�wareas: �Isa-�49-�t6o o Mai�ie`Il�arou: <br /> �;ggKO'�" 2750 Keliey Parkway P.�. �c�6 <br /> Orono, MN 55356 Crystal �r, MN 55323-0066 <br /> To Current Owner: Address: y�� s� �t- /✓-i <br /> City Ordinance 199 requires that each existing on-site sewage trea��t system in Orono be inspected every two years. <br /> The on-site sewage treat�nent system a#the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): . � <br /> - - .:_. . -_ -- - <br /> 1 "CODE SYSTEA�I"An LSTS which meets all the location,design snd construixion atandards of tl�e current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not moet all the locarion,design and construction standards of the curnat Orono <br /> Munioipal C.ode but does meet die three foot separation requirement or iwo foot requireme�t for systems installed 1996 or earlier,and <br /> ��wl»ch is not failing or an i�inent Uueat to publi��alth or safdy. <br /> ( 3 J"NON-COMPLIANT SYSTEM" A prohitrited�S7'S;an IS�'S located within a designated 100-year 800d plain,any ISTS which may <br /> �� or may noi meet all the locarion,design,or cons�ucbon stanc�rds of the ciure�t Urono Municipel Code aad wLich is failing for any <br /> reason;and any ISTS with less than Wrce feet of unsadn�ted soil or sand be4ween the distn'bution device and the limiting soil charactaistics. <br /> TANK CONDIT ION(5-71: � <br /> inspection indicates: <br /> 5 Aunpout notn�at this time. <br /> �Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �7^Z..�03 ). <br /> Ma1ce sure seotic#aaks are�amned Wrea�h�anhole and not throu¢6 white insaectioe�iues. T�is allows for t�e nroner <br /> cleaaias. Keen water sotiner and irou filter dischar�e out of seatic svstem to nroione fife ef drxinfield. Ask oumner to test <br /> alarm 8oat to verifv:slarm i4 sti11 werkiog in vonr�onse. The adarm warns owner ffiat se�tage is tbout to backuo iato basement <br /> 7 Inspection risers missing-taaks could not be inspected. Iflspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped ou#now. <br /> IELD CONDITION 8-10 : � -� <br /> Drainfield is dry,no surfacing evident. , <br /> 9 Some evidence of surfacing,not critica�yet. <br /> 10 Drainfield is sai.urated and visibly discharging untreated effluent to the surface. Contact the City Inspeetor <br /> immediately.Repairs must be complexsd witlun 9U days. <br /> co�rrrs: 1`�0,�..J ,- Sfp�.z �� - (aok v� : <br /> J <br /> . 1 �-�°�=d`� G�`�S- <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the eveat th�t Wis inspaxion report is used w satisfy the requirements for a mortgage or otha�h�ansfer of P�P�Y,be advised tha2 this repott does <br /> not guarantce or cr�tify that � existing syst�will continue to fundion ProperlY, but is merely an opinion of tge edequacy of the system nnder cumut . <br /> conditions based�the ava�7sble�nformation. <br />