Laserfiche WebLink
On the North Sbore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> � � � Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER �� �� CI� ADDRESS Jb� S�C�1 ilUL�./�/I <br /> PERMIT NO.'S. -�'e DATES � CONTRACTORS � <br /> City Ordinance No,210 requires that each on-site sewege treatment system in Orono be i�spected on a regular basis.The on-site sewage <br /> treatment system at the above address has been i�spected and appears to fall into the category checked below. <br /> (This is �an existing system ❑ new construction) <br /> � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> {� 2 Dces not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br /> ��� located, and constructed generally in accorda�ce with previous codes.System appears to be functionin <br /> g properly;no major <br /> upgrading of the system is required at this time. <br /> � 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may �ot meet current City standards for design,construction or location, but is failing to properly treat and <br /> dispose of the current input,and is e�dangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION (m Checked items may require your action) <br /> Tank inspection indicates: ❑ Inspection pipe is loceted directly over tank baffle.(Does not <br /> ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks <br /> ❑ Solida accumulation in tenks indicates they should be pump� have not been pumped out within the last three years,they <br /> ed out this year to help prevent future problems. should be pumped out now. <br /> ❑ Solids accumutation in tanks ia at a critical level. Tanks Drainfield inapection indicates: <br /> should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surfece. Tanks must be pumped ❑ Some eviden�s of surfacing,not criticat yet. <br /> � within 48 hours to eliminate surfa�discharge. ❑ Drainfield is saturated and visibly discharging untreated <br /> �-Ins tion risera mi ' — nks could not be inspected, effluent to the surface. This condition may require replace- <br /> Ins ction risers must be ms ment or additions to drainfield. Contact the City Inspector <br /> at next p pum immediately.Repairs must be completed within 90 days. <br /> t e last three years,thev should 6e oumned out now �Drainfield extent and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> O Soil table,and system condition) O Adequate <br /> ❑ High water table ❑ Low �Fair <br /> ❑ lot size �-Medium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surfa e discharge. <br /> COMMENTS: �'� r <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does�ot guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />