3585 Sixth Ave N - 29-118-23-43-0004
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:27:05 PM
Creation date
2/1/2019 1:26:57 PM
Metadata
Fields
Template:
x Address Old
House Number
3585
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
3585 6th Avenue North
Document Type
Septic
PIN
2911823430004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
On the North Shore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> � � � Crystal Bay,MN 55323 <br /> 473-7357 <br /> OWNER � � �''�IVf''/'�q lYl P . , <br /> !,� ADDRESS �� -S�(�rn L� <br /> PERMIT NO.'S. r�� DATES CONTRACTORS —" <br /> City Ordinance No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage <br /> ueatment system at the abovs address has been inspected and appears to fall into the category checked below. <br /> (This is � an existing systert► ❑ new construction) <br /> � � Meets or exceeds current City standards in ali respects relating to design,construction,and locetion.Appears to be operating <br /> properly. <br /> �2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br /> loceted, and constructed generelly in accordance with previous codes.System appears to be functioning properly;no major <br /> upgrading of the system is required at this time. <br /> � 3 Does not meet current City standards in many respects relating to desig�,construction,or location.Appears to be operating <br /> adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � System may or may not meet current City sta�dards for design,construction ot location,but is failing to properly treat and <br /> 4 dispose of the current input,and is endangering a water suppty,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise cr@ating a public nuisance.P�ease contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION ( m Checked items may require your action) <br /> Tank'nspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not <br /> �Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks <br /> Solida accumulation in tanks indicates they should be pump- have not been pumped out within the last three yesrs,they <br /> ed out thia year to help prevent future problems. should be pumped out now. <br /> ❑ Solida accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: <br /> should be pumped out as soon as possible. ❑ Orainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped O Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated <br /> ❑ Inspection risen misting—tanks could not be inspected. effluent to the surf�e. This condition may require replace- <br /> Inspection risen (4"dia. pipe)must be installed in eech tank ment or additions to drainfield. Contact the City Inspector <br /> et next pumpout. If tenks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they should be pumped out nOw. �'Drainfield extent and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (dePends on aoil types,water Future Expansion <br /> ❑ Soil table,and system conditio�) � Adequate <br /> ❑ High water table Q Low �air <br /> � Lot size •�-Medium Poor <br /> ❑ Lake,wetland,or stream ❑ High ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discharge. <br /> COMMENTS: <br /> ��9 91 <br /> Date of Inspection eptic System Inspector <br /> Note: In the event that this inspection report is used to setisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guara�tee or certify that an existi�g system wilt continue to functio�properly,but is merely an opinion of the adequacy <br /> of the systert►under current conditions based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.