Laserfiche WebLink
— — — <br /> ; ,_ � <br /> � � �� �����v <br /> � <br /> - O O`'� <br /> �� <br /> ,��,�-� �, <br /> ' C ITY of ORONO <br /> ,� � ,� <br /> I�`\ �', �y„�',�'�J � l4 �I�I Municipal Offices <br /> �,�'� �� . , `\���yG'ti/ <br /> � � / Street Address: Mailing Address: <br /> `91fEgg0�� 2750 Kelley Parkway P.O. Box 66 <br /> ��� _ _ �� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �C,7/✓-!C� J ►(���,Y Address:3565 Sixth Ave. N. <br /> Permit #'s:3613, 7418 Dates:4/26/73, 5/14/84 Contractors:Dennis Honebrink, Jerry <br /> Johnson <br /> (This is [ an existing system [ ] new construction) <br /> SYSTEM COMPLIANCE (1-3) : 2 <br /> 1 Code Svstem: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> � Compliant Svstem: Does not meet all rurrent City standards for new construction, <br /> but in most respects appears to be de��igned, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br /> 3 Non-Compliant Svstem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level. <br /> (The saturated soil level [�] has or ( ] has not been identified at this time. If the <br /> saturated soil level has not� been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> 5 Pumpout not needed at this time <br /> � Solids accumulation in tanks indicates they should be pumped out this year. <br /> `�j System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or ] were not <br /> confirmed to be watertight by the licensed pumping contractor. If the anks were not <br /> confirmed to be watertight, this classificai:ion is subject to revision.) <br /> INFIELD CONDITION 11-14 : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system acie and condition, soils, etc. ) : low <br /> COMMENTS: <br /> � �� ��_ , � "�:� ; r/" ,YGr�" —�'�.... <br /> �..__ <br /> Date of Inspection ep „ System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />