Laserfiche WebLink
On the North Shore o f <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> � � � Crystal Bay, MN 55323 � <br /> 473-7357 <br /> OWNER �I�yt� L, G-�'U�i�D1�'�. ADDRESS �7�Ds SIjCI'� ,�/�. M <br /> PERMIT NO.'S. 7 DATES ����9!�3�g� CONTRACTORS � � �$O►'� <br /> City O�dinance No.210 requires that each on-site sewsge treatment system in Orono be inspected on a regular basis.The onsite sewage <br /> Veatme�t system at the above add►eu has been inspected and appears to fall into the category checked below. <br /> (This is �an existing system ❑ new consuuctio�) <br /> � � Meets or exceeds current City standards in all respects relating to design,consuuction,and location.Appears to be operating <br /> properly. <br /> � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br /> loceted, a�d constructed generally in accordance with previoua codes.System appears to be functioning properly;no major <br /> upgrading of the system is required at this time. <br /> � 3 Does not meet current City standards i� many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City standards for desig�,construction or location, but is faiting to properly treat and <br /> dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drai�field replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a pe�mit before work is started. <br /> SYSTEM CONOITION ( m Checked items may require your actio�) <br /> Tank inspection indicates: �-Inspection pipe is located directly over tank baffle.(Does not <br /> ❑ Pumpout not needed at this time, give accurate m�surement of solids accumulation.) If tanks <br /> ❑ Solids aecumulation in tenks indicates they should be pump� have not been pumped out within the lest three yea►s,they <br /> ed out this year to help prevent future problems, should be pumped out now. <br /> O Solids accumulstion in tanks is at a critical level. Tanks Drainfield inspection indicates: <br /> should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. ❑ O�ainfield is saturated and visibly dischargi�g untreated <br /> ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- <br /> Inspection risera (4"dia. pipe)must be i�stalled in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks heve not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they shoutd be pumped out now. ❑ Drainfield exte�t a�d condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> ❑ Soil table and system condition) Adequate <br /> ❑ High water table �Low �Fair <br /> ❑ Lot size ❑Medium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High O Inadequate <br /> ❑ Dreinage ❑System is causing visible <br /> surface discharge. <br /> COMMENTS: <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guarentee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current conditio�s based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />