Laserfiche WebLink
__.._-----------_---..___. <br /> � O� <br /> O ;:,,. O <br /> �� �- CITY of ORONO <br /> , �� <br /> � � � <br /> ,\'�'i, `� �r+,r ,�ti Municipal Offices <br /> � r�.F ;�, .�►G Stroet Address: �15�.-�t49—�6o O M�iling Address: <br /> ��0�" 2750 Kelley Parkway P:O. �eic b6 <br /> Orono, MN 55356 Crystal �r, #�l 55323-0066 <br /> To Current Owner: Address: ��6 S S�� �N C N� <br /> City Ordinance 199 requires that each existing on-site sewage trea�►ent system in Orono be inspected every two years. <br /> T'he on-site sewage treahnent system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-31: �, <br /> -- ---- _-.._. _. _ .. - <br /> _ ---- ___ <br /> 1 "CODE�SI'S`TEM"An�LSTS which meets ali the location,design and construction standards of We aurent Orono Municip�l Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not med all the locatian,desi�►and conshucxion standards of the cwre�t Orano <br /> Municipal C,ode but does mcet ihe three foot separation require�t�1wo�oot reqt�irement for systems installed 1996 or tarlier,and <br /> which is not�ling or an immin�t ihreat to public heaith or safety. <br /> �"NON-CO1vIPLIANT SYSTEM" A pmhibitea iS3s;an ISTs located w;min a aesignacoa loo-year aooa plaiu,any LSTs wWch may <br /> or may not meet all tbe location,design,or conshuction stanc�rds of the cu�t Orono Municigal Code and which is failing for any <br /> reason;and any LSTS widi kss than Wrce fer�of unsaiurated so�7 or sand betvwoen tbe dishi'bution device and the limiting soil characteristics. <br /> TANK CONDTITON(5-'n: <br /> T inspection indicates: <br /> 5 Pumpc�ut not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last P�P�. 1. <br /> Make sere sentic t�aks are na�ued ffirea�h�ahole a�d aot�roa�whiEe iosuection nices This sllows for tLe oroner <br /> clesaing Kcen water softaer aed iron filter discbat�e eut of sentic svstee�to uralong life ef draia5eld Ask nu�ner to test <br /> alarm float ts veritv alarm is stiil workiag i�voar house. T1ie alsrm war�s e�er t�6,t senta�e is about to backun iato basement <br /> 7 Inspection risers missing-tar�ks could not be inspectsd. Inspection rise.rs{4"dia.pipej must be installed in each tank. If <br /> tanks have�ot bcen pumped out within the last t�rce years,they should be putnpal out now. <br /> D INF'IELD CONDITTON 8-10 : � -. <br /> 8 Ihainfield is dry,no surfacing evident. <br /> 9 Sorne evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated e$luent to the surface. Contact the Gity Inspeetor <br /> immadiately.Repairs must be completed within 90 days. <br /> CO S: ��a�t�� \� ��,� �J,� 1�,,,,� - a--- n,��d-- "J� <br /> �.c,� 12�\-Zo\0.. .� ��c� �.S e�.,,-,r�-. c S �r� <br /> Sc(��,i � CS� <br /> \ 0 '�q-o� G``�. <br /> Date of Inspection Mau Bolte�man- Septic System Inspector <br /> Nou: In the eveat th�this inspecxion report is used to sadsfy the requirements for a matgage or otha transfe,r of pmperty,be advised i��is r�ort does <br /> not guarantoe �catify that au existing system will continue W function ProperlY, but is merely an opinia�of the adequacy of d�e system�der cumut <br /> c�ditions b�sed on the availabk�#'amadon. <br />