My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
3465 Sixth Ave N - 29-118-23-43-0011
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:27:09 PM
Creation date
1/23/2019 1:07:53 PM
Metadata
Fields
Template:
x Address Old
House Number
3465
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
3465 6th Avenue North
Document Type
Septic
PIN
2911823430011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
__.._-----------_---..___. <br /> � O� <br /> O ;:,,. O <br /> �� �- CITY of ORONO <br /> , �� <br /> � � � <br /> ,\'�'i, `� �r+,r ,�ti Municipal Offices <br /> � r�.F ;�, .�►G Stroet Address: �15�.-�t49—�6o O M�iling Address: <br /> ��0�" 2750 Kelley Parkway P:O. �eic b6 <br /> Orono, MN 55356 Crystal �r, #�l 55323-0066 <br /> To Current Owner: Address: ��6 S S�� �N C N� <br /> City Ordinance 199 requires that each existing on-site sewage trea�►ent system in Orono be inspected every two years. <br /> T'he on-site sewage treahnent system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-31: �, <br /> -- ---- _-.._. _. _ .. - <br /> _ ---- ___ <br /> 1 "CODE�SI'S`TEM"An�LSTS which meets ali the location,design and construction standards of We aurent Orono Municip�l Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not med all the locatian,desi�►and conshucxion standards of the cwre�t Orano <br /> Municipal C,ode but does mcet ihe three foot separation require�t�1wo�oot reqt�irement for systems installed 1996 or tarlier,and <br /> which is not�ling or an immin�t ihreat to public heaith or safety. <br /> �"NON-CO1vIPLIANT SYSTEM" A pmhibitea iS3s;an ISTs located w;min a aesignacoa loo-year aooa plaiu,any LSTs wWch may <br /> or may not meet all tbe location,design,or conshuction stanc�rds of the cu�t Orono Municigal Code and which is failing for any <br /> reason;and any LSTS widi kss than Wrce fer�of unsaiurated so�7 or sand betvwoen tbe dishi'bution device and the limiting soil characteristics. <br /> TANK CONDTITON(5-'n: <br /> T inspection indicates: <br /> 5 Pumpc�ut not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last P�P�. 1. <br /> Make sere sentic t�aks are na�ued ffirea�h�ahole a�d aot�roa�whiEe iosuection nices This sllows for tLe oroner <br /> clesaing Kcen water softaer aed iron filter discbat�e eut of sentic svstee�to uralong life ef draia5eld Ask nu�ner to test <br /> alarm float ts veritv alarm is stiil workiag i�voar house. T1ie alsrm war�s e�er t�6,t senta�e is about to backun iato basement <br /> 7 Inspection risers missing-tar�ks could not be inspectsd. Inspection rise.rs{4"dia.pipej must be installed in each tank. If <br /> tanks have�ot bcen pumped out within the last t�rce years,they should be putnpal out now. <br /> D INF'IELD CONDITTON 8-10 : � -. <br /> 8 Ihainfield is dry,no surfacing evident. <br /> 9 Sorne evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated e$luent to the surface. Contact the Gity Inspeetor <br /> immadiately.Repairs must be completed within 90 days. <br /> CO S: ��a�t�� \� ��,� �J,� 1�,,,,� - a--- n,��d-- "J� <br /> �.c,� 12�\-Zo\0.. .� ��c� �.S e�.,,-,r�-. c S �r� <br /> Sc(��,i � CS� <br /> \ 0 '�q-o� G``�. <br /> Date of Inspection Mau Bolte�man- Septic System Inspector <br /> Nou: In the eveat th�this inspecxion report is used to sadsfy the requirements for a matgage or otha transfe,r of pmperty,be advised i��is r�ort does <br /> not guarantoe �catify that au existing system will continue W function ProperlY, but is merely an opinia�of the adequacy of d�e system�der cumut <br /> c�ditions b�sed on the availabk�#'amadon. <br />
The URL can be used to link to this page
Your browser does not support the video tag.