Laserfiche WebLink
- - - <br /> ,,_ <br /> � ��\��, <br /> O 0��. <br /> '' CITY of ORONO <br /> '�I .� '�,'�i�� � '�/� <br /> ���', L ���' �6' � !G�� Municipal Offices <br /> � � ���� � `��� G��� Street Address: Mailing Address: <br /> �. <br /> �`��C'EggO�'� 2750 Kelley Parkway P.O. Box 66 <br /> ��=_—_� ' Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: � � �„ Address:3405 Sixth Ave. N. <br /> Permit #'s:6036 Dates:7/2/80 Contractors:Hayes Exc. <br /> (This is � an existing system [ ] new construction) <br /> YSTEM COMPLIANCE 1-3 : 1 <br /> 1 Code Svstem: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br /> 3 Non-Compliant Svstem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level . <br /> (The saturated soil level ( ] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> ,��. K CONDITION (5-9) : 5 <br /> (5) Pumpout not needed at this time <br /> � Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [� were not <br /> confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> AINFIELD CONDITION 11-14 : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system acie and condition, soils, etc. ) : medium <br /> COMMENTS: The fire pit in the drainfield must be filled to prevent future problems. <br /> ��-�� .,-...a.!� .� ,�--_—.__. <br /> Date of Inspection Sept' System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 � FAX 473-0510 <br />