Laserfiche WebLink
�o� <br /> O�,�:; O <br /> -� � CITY of ORONU <br /> ,�, `r������,�,,-�. � <br /> , �'��,�, l4 Municipal Offices <br /> '�► '�,,=,,, <br /> � ���'��� '1'�� G� � <br /> �9 �,������, 4� Street Address: Mailing Address: <br /> �C�;ggO 2150 Kelley Parkway P.O. Boz 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> Owner_,���1 � �� Address:3240 Sixth Ave. N. <br /> Permit #'s:8415 Dates:9/25/96 Contractors:Hayes Sxc. <br /> (This is [ ] an existing system � new construction) <br /> STEM COMPLIANCE 1-3 : 1 <br /> 1 - Code Svstem: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant Svstem: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br /> 3 Non-Compliant Svstem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level. <br /> (The saturated soil level ,J�] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> �ANK CONDITION (5-9) : 5 <br /> Pumpout not needed at this time <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks �, were or [ ] were not <br /> confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> INFIELD CONDITION 11-14 : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and con3ition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (svstem acTe and condition, soils, etc.) : low <br /> COMMENTS: <br /> �->3�7 � <br /> Date of Inspection Sep c System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this repo:rt does not guarantee that an existing system will continue <br /> to function properly, but indic<ites the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />