My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
01-22-2019 Planning Commission Packet
Orono
>
Agendas, Minutes & Packets
>
Planning Commission
>
Packets
>
2010-2019
>
2019
>
01-22-2019 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2019 10:58:43 AM
Creation date
1/23/2019 10:58:05 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
334
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br /> www.SepticResource.com (vers 15.2) <br /> Property Owner: Stonewood LLC. Date: 6/18/2018 <br /> Site Address: Proposed Lot1 PID: 0211723230005 <br /> Comments: Site A <br /> instructions: =enter data =adjust if desired = computer calculated - DO NOT CHANGE! <br /> )) 5 bedroom Type I Residential System <br /> 21 750 GPD design flow <br /> 3 Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br /> 4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br /> Tank options: none <br /> 5) 1.21GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br /> 6) 10.0 ft rockbed width 63.0 ft rockbed length <br /> 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> 8) 3 laterals 61.0 feet long 21.0 perfs / lateral 63 perfs total <br /> (1/2 a perf means the first perf starts at the middle feed manifold) <br /> 9) 7/32 inch perfs at 1 feet residual head gives 0.56 gpm flow rate per perforation <br /> for this perf size & spacing, & pipe size on line 12, max perfs/lateral= 30 , line#8 must be less --> OK <br /> 10) 4.0 doses per day (4 minimum) <br /> i) 188 gallons per dose (treatment volume) <br /> 2.00 5x <br /> 12) 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> 13) feet of 2.0 inch supply line leads to ##### gallons of drainback volume <br /> (Tip: "top feed" manifold to control the drainback) <br /> )4) ######gallons TOTAL pump out volume (treatment+ drainback) <br /> 15) feet vertical lift from pump to mound laterals, leads to a: <br /> )ci 36 GPM G ##### feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> :7) 750 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br /> leads to a <br /> )a) ######inch swing on Demand float, or timed dosing of ##### min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow) ##### hrs OFF test and adjust as necessary) <br /> )9) 12 inches from bottom of tank to"Pump OFF"float <br /> 20) ###### inches from bottom of tank to"Pump ON"float, or 12 inches to"Timer ON"float if time dosed <br /> 2)) ###### inches from bottom of tank to"Hi Level"float, or ##### inches to"Hi Level"float if time dosed <br /> 22) ######gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.