Laserfiche WebLink
,,��°� <br /> ,'o 0 <br /> CITY of ORONO <br /> .��,, '�' �y �� ', lS� Municipal Offices <br /> � . l .. r t���i1A �/� <br /> �� � 1 �,a ,� Street Address: Mailing Address: <br /> \lt'�g0'�' 2750 Kelley Parkway PA. Box 66 <br /> Orona, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �rei')� '"� L' �C� Address: 3025 3ixth Ave. N. <br /> Permit #'s: 6233 Dates: 12/18/BO Contractors: Thompson Plbg. <br /> (This is (x] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) :�� <br /> 1 Code System: Meets r exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> � Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [X] or is not [ ] identified under this septic system. If the ' <br /> saturated soil level is not id�ntified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9� <br /> 5 Pumpout not neede at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [� or are not [ ] water tight or the condition is [ ] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> D�tP,INFIELD CONDITION (11-14) : � <br /> 11 Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 0.5 feet and the system is non-compliant. Repair or replacement of the septic <br /> system is required by 12/31/2005. <br /> v' <br /> �L� ' � J � � � <br /> Date of Inspection Sep System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />