Laserfiche WebLink
� o� <br /> O�� o <br /> ,� ��y�� CITY of ORONO <br /> �� ::;_ �, <br /> � !� MunicipalOfPces <br /> 'r�,� � ° ', ��°�� Gti <br /> �' Street Addresr. Mailina Address: <br /> ��'�gg0�'� 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: Address: 2905 Sixth Ave. N. <br /> Permit #'s: 6H04 Dates: 9/15/82 Contractors: Thou4pson P1bQ. <br /> (This is X] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> � Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturatad soil level is [x or fs not [ ] identified uadar this septic system. If the <br /> saturated soil leval is not idantified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 5 <br /> 5 Pumpout not needed at this time. <br /> Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 The tank or tanks meet the definition of a cesspool and must be replaced within 10 months. <br /> (Tha tanks are �] or are not [ ] water tiQht or the condition is [ ] uakaowu. If the tanks <br /> are not confirnued to be watertiQht, this classificatioa is subject to revision.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> � 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> CONQ4ENT5: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 2 feet and the system is non-compliant. No repair or replacement <br /> septic system is required at this time. <br /> � - -� <br /> Da e of Inspec ion S ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />