My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-00234 - alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Permits/Inspections
>
2018-00234 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:41 PM
Creation date
1/18/2019 3:50:20 PM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• s <br /> • <br /> Installation B210LPBP: Bulk pack of B210LP;package contains 10. <br /> FSP-851(A)plug-in detectors use a separate base to simplify B501(A):Standard European flangeless mounting base. <br /> installation, service, and maintenance. A special tool allows B501 BP: Bulk pack of B501;package contains 10. <br /> maintenance personnel to plug in and remove detectors with- <br /> out using a ladder. B200S(A): Intelligent, programmable sounder base capable <br /> Mount base(all base types)on an electrical backbox which is of producing sound output in high or low volume with ANSI <br /> at least 1.5" (3.81 cm) deep. For a chart of compatible junc- Temp aANSI Temporal 4, continuous tone, marching <br /> tion boxes,see DN-60054. tone,anndd custom tone. <br /> B200SR(A): Intelligent sounder base capable of producing <br /> NOTE: 1) Because of inherent supervision provided by the SLC sound output with ANSI Temporal 3 or continuous tone. <br /> loop, end-of-line resistors are not required. Wiring 'T-taps" or Replaces 8501 BH series bases in retrofit applications. <br /> branches are permitted for Style 4 (Class "B") wiring. 2) When <br /> using relay or sounder bases, consult the ISO-X(A) installation B224RB(A): Plug-in System Sensor relay base. Screw ter- <br /> sheet /56-1380 for device limitations between isolator modules minals:up to 14 AWG(2.0 mm2).Relay type: Form-C. Rating: <br /> and isolator bases. 2.0 A @ 30 VDC resistive;0.3 A @ 110 VDC inductive; 1.0 A <br /> @ 30 VDC inductive. <br /> Agency Listings and Approvals <br /> B224BI(A): Plug-in System Sensor isolator detector base. <br /> These listings and approvals apply to the modules specified Maximum 25 devices between isolator bases. <br /> in this document. In some cases,certain modules or applica- <br /> tions may not be listed by certain approval agencies,or listing ACCESSORIES <br /> may be in process. Consult factory for latest listing status. F110: Retrofit flange to convert B210LP(A) to match the <br /> • UL Listed:S1115. B710LP(A) profile, or to convert older high-profile bases to <br /> ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP- low profile. <br /> • 851TA). F110BP: Bulk pack of F110; package contains 15. <br /> • MEA Listed:225-02-E. F210: Replacement flange for B210LP(A)base. <br /> • FM Approved. RA100Z(A): Remote LED annunciator. 3—32 VDC. Mounts <br /> • CSFM:7272-0028:0206. to a U.S. single-gang electrical box. For use with B501(A) <br /> • Maryland State Fire Marshal: Permit#2122. and B210LP(A)bases only. <br /> • BSMI:CI313066760036. SMB600:Surface mounting kit <br /> • CCCF:Certif.#2004081801000017(FSP-851T) M02-04-00:Test magnet. <br /> Certif.#2004081801000016(FSP-851). <br /> U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/ M02-09-00:Test magnet with telescoping handle. <br /> • 0(NFS2-640/NFS-320/NFS-320C,excluding B210LP(A)). XR2B: Detector removal tool. Allows installation and/or <br /> • Lloyd's Register: 11/600013 (NFS2 640/NFS 320/NFS- removal of detector heads from bases in high ceiling applica- <br /> 320C,excluding B210LP(A)). tions. <br /> XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 <br /> Product Line Information m)sections. <br /> NOTE:"A"suffix indicates ULC Listed model. T55-127-010: Detector removal tool without pole. <br /> FSP-851: Low-profile intelligent photoelectric sensor. Must BCK-200B: Black detector covers for use with FSP-851(A) <br /> be mounted to one of the bases listed below. only; box of 10. <br /> FSP-851A:Same as FSP-851 but with ULC listing. WCK-200B: White detector covers for use with FSP-851(A) <br /> FSP-851T: Same as FSP-851 but includes a built-in 135°F only; box of 10. <br /> (57°C)fixed-temperature thermal device. <br /> FSP-851TA:Same as FSP-851T but with ULC listing. <br /> FSP-851 R: Low-profile intelligent photoelectric sensor, <br /> remote test capable. For use with DNRA/DNRW. <br /> FSP-851RA: Same as FSP-851R but with ULC listing. For <br /> use with DNRA. <br /> INTELLIGENT BASES <br /> NOTE:"A"suffix indicates ULC Listed model. NOTIFIER®is a registered trademark of Honeywell International Inc. <br /> NOTE:For details on intelligent bases,see DN-60054. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> of this document is strictly prohibited. <br /> B210LP(A): Standard U.S. flanged low-profile mounting <br /> base. <br /> 1S0 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. <br /> ENGINEERING&MANIHCTIRING All specifications are subject to change without notice. <br /> QUALITY SYSTEMS <br /> For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. <br /> www.notifier.com <br /> Page 2 of 2—DN-6935:E•2/11/2015 <br />
The URL can be used to link to this page
Your browser does not support the video tag.