My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-00234 - alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Permits/Inspections
>
2018-00234 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:41 PM
Creation date
1/18/2019 3:50:20 PM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
— <br /> DN-6861:C•A0-260 <br /> • <br /> NCM-W, NCM-F <br /> ONYX® Series ® NOTIFIER® <br /> Network Communications Modules by Honeywell <br /> Network Systems <br /> General <br /> The Network Communications Module (NCM) provides <br /> NOTIFIER Intelligent Fire Alarm Control Panels, and NCA and <br /> NCA-2 Network Control Annunciators with a means to connect • t,, , <br /> to NOTI•FIRE•NETTM. Two types of NCM are available: <br /> NCM-W for connecting nodes with twisted-pair wire, and <br /> NCM-F for connecting nodes with fiber-optic cable. <br /> NOTE: Do not mix NCM and High Speed(HS)NCM on the same <br /> system. <br /> NCM-W Features <br /> • Supports twisted-pair wire medium. <br /> • <br /> NFPA Style 4(Class B)operation or NFPA Style 7(Class A) <br /> operation. <br /> • Two programmable data thresholds. NCM-W <br /> • Transformer coupling provides electrical isolation between • Maximum attenuation is 8 dB with 62.5/125 pm fiber and <br /> nodes. 4.2 dB with 50/125 pm fiber. <br /> • Pluggable terminal wiring with strain relief. • Wavelength (1): 820 nanometers (use standard 850 nm <br /> • Pluggable service connector(feeds signal directly through) fiber). <br /> in the event that power must be removed from a node. • Connectors:ST®style. <br /> • 312.5 Kbaud transmission rate. • 312.5 Kbaud transmission rate. <br /> • Data is regenerated at each node. • Data is regenerated at each node. <br /> • Two network ports to allow simultaneous connection to fire • Two network ports to allow simultaneous connection to fire <br /> alarm control panel and to programming computer. alarm control panel and to programming computer. <br /> • Enables software and database upload/download over • Enables software and database upload/download over <br /> NOTI•FIRE•NETTM. NOTI•FIRE•NETTM <br /> • Repeaters are available to increase signal. • Repeaters are available to increase signal. <br /> • Repeaters may be utilized to switch media type. • Repeaters may be utilized to switch media type. <br /> • Up to 3,000 feet (914.4 m) between nodes in a point-to- • Up to 3,000 feet (914.4 m) between nodes in a point-to- <br /> point fashion (actual distance varies with wire quality). point fashion (actual distance varies with wire quality). <br /> NCM-W Interconnections:When wiring consecutive NCM-W NCM-F Interconnections: When wiring consecutive nodes/ <br /> boards, wiring may enter or exit at Port A or Port B. NCM-W repeaters, fiber cable must exit one board on Transmit (TX) <br /> port-to-port wiring is not polarity sensitive; use of Port A or and enter the next node/repeater on Receive (RX).The fiber- <br /> Port B is arbitrary.An NCM-W may be connected to any of the optic pair (RX, TX)from Port A of one node/repeater may be <br /> following devices: MIB-W, MIB-WF, NAM-232W, NCM-W (in connected to either Port A or Port B of another node/repeater. <br /> another panel), NCS-W network connection,RPT-W, RPT-WF. An NCM-F may be connected to any of the following devices: <br /> NCM-W Switch Functions:The NCM-W provides two sets of MIB-F, MIB-WF, NAM-232F, another NCM-F, NCS-F network <br /> switches to simplify network setup. Enable ground fault connection, RPT-F, RPT-WF. <br /> detection by setting "ON"switch SW103 (Channel A); switch <br /> SW101 (Channel B). Activate on-board end-of-line resistors Common Specifications <br /> by setting"ON"switch SW100(Channel A);switch 102(Chan- <br /> nel B). NOTE: Correct configuration is dependent on network Temperature and humidity ranges: This system meets <br /> design;refer to the NOTI•FIRE•NETTm manual. NFPA requirements for operation at 0°C to 49°C (32°F to <br /> 120°F); and ata relative humidity (noncondensing) of 85% at <br /> For further information and diagrams, refer to the NCM Instal- 30°C(86°F)per NFPA,and 93%±2%at 32°C±2°C(89.6°F± <br /> lation Document,51533. 1.1°F) per ULC. However, the useful life of the system's <br /> standby batteries and the electronic components may be <br /> NCM-F Features adversely affected by extreme temperature ranges and humid- <br /> • Supports fiber-optic medium. ity. Therefore, it is recommended that this system and all <br /> peripherals be installed in an environment with a nominal room <br /> • NFPA Style 4(Class B)or Style 7(Class A)operation. temperature of 15°C to 27°C(60°F to 80°F). <br /> • Data is immune to all environmental noise. Power supply:24 VDC @ 110 mA. <br /> • Optical isolation prevents ground loops. <br /> • NOTI•FIRE•NETT",fiber-optic medium. <br /> • Fiber type: 62.5/125 micrometers (multimode); or 50/125 <br /> micrometers(multimode). <br /> DN-6861:C•10/04/2010—Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.