<br /> Grinnell Grooved Fire Protection Products
<br /> Grooved Fittings
<br /> General Material: Limited
<br /> Cast:Figures:201,210,219,250,260,501,510,
<br /> Description 519,510DE,501S,510S and 519S- Warranty
<br /> See Fire Protection Ductile iron conforming to ASTM A 536, Products manufactured by Tyco Fire Products are
<br /> LPCBVd SSubmittal Sheet for Grade 65-45-12 warranted solely to the original Buyer for ten(10)
<br /> Pressure Rating and Fabricated Steel: Figures 391, 392, 393, 312, years against defects in material and workmanship
<br /> a Listing/Approval
<br /> Information 313, 321,327, 341 and 350 Carbon Steel,
<br /> (Sizes 11/4" 6"are Schedule 40);
<br /> when paid for and properiyinstalled and maintained
<br /> -
<br /> ® (Sizes 8"-12"are Schedule 30), under normal use and service. This warranty will
<br /> (Sizes 8"-12"ming to ASTMA5le30),3 B
<br /> expire ten(10)years from date of shipment by Tyco
<br /> confoFire Products. No warranty is given for products or
<br /> The grooved fittings provide an economical Protective Coatings: components manufactured by companies not
<br /> and efficient method of changing direction, •Non-lead orange paint affiliated by ownership with Tyco Fire Products orfor
<br /> adding an outlet, reducing, or capping •Fire brigade red(optional)non-lead paint products and components which have been subject
<br /> grooved piping systems. Grooved fittings •Hot dipped galvanized conforming to ASTM to misuse,improper installation,corrosion,orwhich
<br /> are available in durable ductile iron or A-153 have not been installed, maintained, modified or
<br /> fabricated steel as indicated. repaired in accordance with applicable Standards of
<br /> Note: Figure 510S and 519S fittings are Ordering the National Fire Protection Association (NFPA),
<br /> special short radius fittings with smaller and/orthestandards of any other Authorities Having
<br /> center to end dimensions than standard Procedure Jurisdiction.Materials found by Tyco Fire Products
<br /> grooved fittings. Depending on the size and When placing an order,indicate the full product to be defective shall be either repaired orreplaced,at
<br /> coupling used,there maybe interferences at name.Please specifythe quantity,figure number, Tyco Fire Products'sole option.Tyco Fire Products
<br /> the bolt pads that require repositioning of the wall thickness,and size. neither assumes, nor authorizes any person to
<br /> coupling orientation. The use of flange Grinnell Grooved Piping Products, valves, assumeforit,any otherobligation in connectionwith
<br /> adapters is not recommended with Figures accessories and other products are available the sale of products or parts of products.Tyco Fire
<br /> 510S and 519S fittings. Contact Tyco Fire throughout the U.S.,Canada,and internationally, Productsshallnotbe responsibleforsprinklersystem
<br /> Products for details. through a network of distribution centers.You designerrorsorinaccurateorincompleteinformation
<br /> WARNING may write directly or call 215-362-0700 for the supplied by Buyer or Buyer's representatives.
<br /> The Fittings described herein must be installed distributor nearest you. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE
<br /> and maintained in compliance with this document, LIABLE,IN CONTRACT,TORT,STRICT LIABILITY
<br /> as well as with the applicable standards of the Care and OR UNDER ANY OTHER LEGAL THEORY, FOR
<br /> National Fire Protection Association,in addition Maintenance INCIDENTAL, INDIRECT, SPECIAL OR
<br /> to the standards of any other authorities having CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT
<br /> jurisdiction. Failure to do so may impair the The owner is responsible for the inspection, LIMITED TO LABOR CHARGES,REGARDLESS OF
<br /> performance of this device. testing,and maintenance of their fire protection WHETHERTYCOFIREPRODUCTSWASINFORMED
<br /> The owner is responsible for maintaining their system and devices in accordance with the ABOUT THE POSSIBILITY OF SUCH DAMAGES,
<br /> fire protection system and devices in proper applicable standards of the National Fire Protection AND IN NO EVENT SHALL TYCO FIRE PRODUCTS'
<br /> operating condition.The installing contractor or Association (e.g., NFPA 25), in addition to the LIABILITY EXCEED AN AMOUNT EQUAL TO THE
<br /> sprinkler manufacturershould be contacted with standards of any authority having jurisdiction. SALES PRICE.
<br /> any questions. The installing contractor or product manufacturer THE FOREGOING WARRANTY IS MADE INLIEU OF
<br /> should be contacted relative to any questions. ANY AND ALL OTHER WARRANTIES EXPRESS OR
<br /> Technical Any impairment must be immediately corrected. IMPLIED. INCLUDING WARRANTIES OF
<br /> It is recommended that automatic sprinkler MERCHANTABILITY AND FITNESS FOR A
<br /> Data systems be inspected,tested,and maintained by PARTICULAR PURPOSE.
<br /> Approvals: a qualified Inspection Service.
<br /> UL,FM,ULC,VdS,and LPCB;
<br /> Note: See Fire Protection Submittal Sheet for
<br /> exact Listing/Approval information.
<br /> Page 1 of 6 September 2004 TFP1810