on a half-chassis and one NFS2-3030 or NCA-2 mounted on a ABF-4B Annunciator Flush Box <br /> half-chassis. The right side houses a microphone/handset ABS-1TB(C)Annunciator Surface Box <br /> well.The CA-2 assembly includes CMIC-1 microphone.ADDR ABS-1B(C)Annunciator Surface Box <br /> Series doors with two-tier visibility are available for use with <br /> the CA-2 configuration: ADDR-B4, ADDR-C4, ADDR-D4 ABS-2B Annunciator Surface Box <br /> (below). ABS-2D(C)Annunciator Surface Box <br /> ADDR-B4:Two-tier-sized door designed for use with the CA-2 ABS-4D(C)Annunciator Surface Box <br /> chassis configuration.ADDR Series doors are similar to CAB- SEISKIT-CAB: Seismic mounting kit. Required for seismic- <br /> 4 Series "DR" doors, but a clear window space exposes the certified applications with NFS2-3030 and other equipment <br /> top two tiers of the CAB-4 enclosure.Use an SBB-B4 backbox mounted in CAB-4 Series Enclosures.Includes battery bracket <br /> with the ADDR-B4. See DN-7045, DN-6857. for two 26 AH batteries. <br /> ADDR-C4:Three-tier-sized door designed for use with the CA- SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery <br /> 2 chassis configuration. ADDR Series doors are similar to bracket for two 55 AH batteries. <br /> CAB-4 Series "DR"doors, but a clear window space exposes <br /> the top two tiers of the CAB-4 enclosure. Use an SBB-C4 OTHER OPTIONS <br /> backbox with the ADDR-C4. See DN-7045, DN-6857. 411:Slave digital alarm communicator. See DN-6619. <br /> ADDR-D4: Four-tier-sized door designed for use with the CA-2 411 UDAC: Digital alarm communicator. See DN-6746. <br /> chassis configuration.ADDR Series doors are similar to CAB- IPDACT-2, IPDACT Internet Monitoring Module: Connects <br /> 4 Series "DR" doors, but a clear window space exposes the to primary and secondary DACT telephone output ports for <br /> top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox internet communications over customer-provided Ethernet <br /> with the ADDR-D4. See DN-7045, DN-6857. connection. Requires compatible Teldat VisorALARM Central <br /> DPA-1: Dress panel, used with the CA-1 chassis when contig- Station Receiver.Can use DHCP or static IP. See DN-60408. <br /> ured with a DVC-EM, DVC-KD,and CMIC-1. See DN-7045. IPCHSKIT: IP Communicator Chassis Mounting Kit. For <br /> DPA-2: Dress Panel used with the CA-2 chassis assembly. mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 <br /> DPA-1A4: Dress panel, used with the CA-1 chassis when the series chassis. Use IPENC for external mounting applications. <br /> CMIC-1 is not used. Provides mounting options on right two IPSPLT:Y-adapter option allow connection of both panel dialer <br /> bays for two ACS annunciators, or for blank plates. See DN- outputs to one IPDACT-2/2UD cable input. <br /> 7045. IPENC: External enclosure for IPDACT, includes IPBRKT <br /> ADP-4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of mounting bracket; Red;for black,order IPENC-B. <br /> a CAB-4 series enclosure. Used with ACS series annuncia- IPGSM-4G:Internet and Digital Cellular Fire Alarm Communica- <br /> tors. tor. Provides selectable configurable paths:cellular only, IP only, <br /> BMP-1: Blank module for unused module positions. or IP primary with cellular backup. Connects to the primary and <br /> DP-1B: Blank dress panel. Provides dead front panel for secondary ports of a DACT. For Canadian applications order <br /> unused tiers;covers DAA2/DAX series or AA-series amplifier. IPGSM-4GC. See DH 60769. <br /> Batteryplate, required. NOTE:For other options including compatibility with retrofit equip- <br /> BP2-4: q ment,refer to the panel's installation manual,the SLC manual,and <br /> CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 the Device Compatibility Document. <br /> amplifiers. <br /> CHS-4N:Chassis for mounting up to four APS-6Rs. System Specifications <br /> CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. SYSTEM CAPACITY <br /> Mounts up to six modules in any CAB-4 series row. • Intelligent Signaling Line Circuits 1 expandable to 10 <br /> NFS-LBB: Battery Box.The NFS-LBB is used to mount up to • Intelligent detectors 159 per loop <br /> two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x • Addressable monitor/control modules 159 per loop <br /> 14"(356 mm)high x 7.75" (197 mm)deep. Door:24.125"(613 <br /> mm)wide x 14.25" (362 mm)high;door adds 0.0625"(approx. • Programmable software zones over 2000 <br /> 1.6 mm)to depth. • ACS annunciators <br /> BACKBOXES per CPU2-3030 32 address x 64 or 96 points <br /> NOTE:"C"suffix indicates ULC Listed model. NOTE: The CPU2-3030 can support up to 96 annunciator <br /> address points per ACM-24AT/-48A. <br /> BB-100: Backbox for batteries and power supplies. The BB- <br /> 100 is used to mount up to two 100 AH batteries and power SPECIFICATIONS <br /> supply,if needed.30" (76.20 cm)wide x 25" (63.50 cm)high x Primary Input Power: <br /> 7.5"(19.05 cm)deep;depth includes door. -AMPS-24: 110-120 VAC,50/60 Hz,4.5 A maximum. <br /> BB-200: Backbox for batteries and power supplies. Holds up -AMPS-24E:240 VAC,50/60 Hz,2.25 A maximum. <br /> to four 100 AH batteries (200 AH capacity) and power supply. <br /> 30" (76.20 cm) wide x 36" (91.44 cm) high x 7.5" (19.05 cm) DC Output: <br /> deep;depth includes door. -Main 24 VDC: Up to 5.0 A <br /> BB-UZC: Backbox for housing the UZC-256 for applications -Aux 24 VDC:Up to 5.0 A <br /> where the UZC will not fit in panel enclosure. Black; for red, -5 VDC:Up to 0.15 A. <br /> order BB-UZC-R. See DN-3404. Current draw(Standby/Alarm): <br /> ABF-1B(C)Annunciator Flush Box -CPU2-3030D board:0.340 A. <br /> ABF-1 DB(C)Annunciator Flush Box with Door.UUULC Listed. -CPU2-3030ND board:0.120 A. <br /> ABF-2B Annunciator Flush Box -LCM-320:0.130 A. <br /> ABF-2DB(C)Annunciator Flush Box with Door -LEM-320:0.100 A. <br /> DN-7070:P•3/8/17-Page 7 of 8 <br />