- <br /> TRUSTED WORLDWIDE SINCE 1908 <br /> az'1eg <br /> STARTERPAQ 13D RESIDENTIAL <br /> FIRE PUMP SPECIFICATIONS <br /> STARTERPAQ <br /> This specification covers the manufacturing and supplying of <br /> a packaged 13D RESIDENTIAL FIRE PUMP SYSTEM including <br /> a self-priming, closed coupled, end suction pump and <br /> basic manifold system. Pump system can be supplied with <br /> complete control panel as defined below. Panel is optional, <br /> but is factory recommended. Full skid mount is optional, but <br /> factory recommended. <br /> STARTERPAQ PUMP & MOTOR <br /> 2 HP Pump. Manufacturer's ► The pump shall be either an ES2 (11 amp) or ES3 (12amp) <br /> design subject to change. <br /> ► Pump shall be a self-priming centrifugal jet pump <br /> STARTERPAQ PERFORMANCE 10. Pump shall be of single stage design <br /> ► Pump shall have a casing construction of cast iron and a <br /> technopolymer impeller <br /> ARTERPAQ ES2 PERFORMANC <br /> ► Pump casing shall include a priming plug for ease of <br /> ► 0 • (churn) @ 90 psi <br /> priming and air elimination <br /> ► 10 gp (i? 81 psi ► Pump Motor shall be 230V based and the ES2 will have a <br /> ► 12 gpm @ '• psi FLA rating of 11 amps and the ES3 will have a FLA rating <br /> ▪ 20gpm @69p-: of 12 amps <br /> ► 24 gpm @ • psi ► Pump Motor shall be Totally Enclosed and Fan Cooled(TEFC) <br /> ► 26 gp 58 psi ► Pump Motor shaft shall be Stainless Steel <br /> ► 30 •m @ 53 psi ► Pump Motor shall make use of oversized grease ball <br /> ► '2 gpm @ 51 psi bearings that are designed to be maintenance-free; <br /> ► Max Flow @ 34 gpm sealed for life <br /> STARTERPAQ ES3 PERFORMANCE ► Pump Motor shall have an integrated pressure switch <br /> ► 0 gpm (churn) @ 72 psi pre-set to start when pressure drops to below 40psi <br /> ► 10 gpm @ 65 psi and reset when pressure increases to above 60psi. If <br /> ► 20 gpm @ 58 psi a control panel as defined below is not provided it is up <br /> ► 25 gpm @ 55 psi to the designer or installing contractor to confirm that <br /> ► 30 gpm @ 51 psi the demand of a single sprinkler head creates enough <br /> ► 35 gpm @ 47 psi demand to keeps system pressure below 60psi. If this is <br /> ► 40 gpm @ 45 psi not possible then the pressure switch should be adjusted <br /> ► 45 gpm @ 40 psi so the start and reset points are increased to a point the <br /> ► 50 gpm @ 25 psi demand of single head does not reset the pressure switch. <br /> LEARN MORE <br /> •••0°. <br /> #DemandDarley ON STARTERPAQ.COM <br /> 1.800.4.DARLEY • DARLEY.COM • in V <br />