My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Fire Suppression System
Orono
>
Property Files
>
Street Address
>
M
>
Mooney Lake Drive (Formeraly 300 Sixth Ave N)
>
1180 Mooney Lake Drive - 25-118-23-41-0016
>
Land Use
>
Fire Suppression System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:07 PM
Creation date
1/18/2019 2:18:42 PM
Metadata
Fields
Template:
x Address Old
House Number
1180
Street Name
Mooney Lake
Street Type
Drive
Address
1180 Mooney Lake Drive
Document Type
Land Use
PIN
2511823410016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cove'r Plate Finishesi') Table H <br /> Standard Finishes Special Application Finishes <br /> White Polyester Off White Paint Black Paint Raw Brass <br /> Chrome Plated Bright Brass Finished Bronze Black Plated <br /> Satin Chrome Stainless Steel Custom Color <br /> CIad131 Paint(2) <br /> Notes: <br /> 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. <br /> 2. Custom color paint is semi-gloss,unless specified otherwise. <br /> 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side.Cover plates <br /> are not listed or approved as corrosion resistant.Stainless steel clad cover plates are not available perforated. <br /> Installation Dimensions Table J <br /> Recommended Min.to Min.to Max. <br /> Cover Plate Cover Plate Max.Face Dropped Deflector <br /> Cover Hole Diameter Cover Plate <br /> Sprinkler Diameter Adjustment of Fitting to Distance below <br /> Plate in Ceiling Temperature <br /> Model inch inch Ceilingt'� Ceiling p <br /> Model inch Rating <br /> (mm) (mm) (mm) inch inch <br /> (mm) (mm) <br /> RFC30 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F <br /> RFC43 RFC (84) (67) (13) (38 to 51) (13 to 25) (57°C) <br /> RFC49 <br /> 135°F12> <br /> RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) <br /> (84) (67) (19) (38 to 57) (6 to 25) or 165°F13> <br /> (74°C) <br /> Notes: <br /> 1. Face of fitting to ceiling dimensions are based on a nominal thread make up.Verify dimensions based on fitting and thread sealing method prior <br /> to installation.A 1/2"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available where necessary for replacement of existing sprinklers. <br /> 2. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). <br /> 3. For use with 212°F(100°C)temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F(66°C). <br /> Installation <br /> Model RFC series sprinklers are intended to be installed in ac- Do not exceed the maximum recommended torque. Exceeding <br /> cordance with NFPA 13,NFPA 13R,or NFPA 13D,as well as the the maximum recommended torque may cause leakage or im- <br /> requirements of applicable authorities having jurisdiction.Mod- pairment of the sprinkler. Use care when inserting or removing <br /> el RFC series sprinklers must not be installed in ceilings with the wrench from the sprinkler to avoid damage to the sprinkler. <br /> positive pressure in the space above. Ensure that the 4 slots in <br /> the cup are open and unobstructed following installation.Model Install the cover plate by hand by pushing the cover plate into <br /> RFC series sprinklers are shipped with a protective cap that the cup and turning the cover in the clockwise direction until it <br /> should remain on the sprinkler until installed.The protective cap is tight against the ceiling. <br /> should be replaced following installation of the sprinkler and <br /> permanently removed only when the cover plate is installed and <br /> the sprinkler system is placed in service following construction. Application <br /> Model RFC series sprinklers are installed with the Model FC Model RFC series sprinklers are intended for installation where <br /> wrench.The use of any other wrench to installed Model RFC se- residential sprinklers are permitted or required by NFPA 13, <br /> ries sprinklers is not permitted and may damage the sprinkler. NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- <br /> Temporarily remove the protective cap during installation of the dent residential sprinklers. <br /> sprinkler.Insert the Model FC wrench over the sprinkler until the <br /> wrench engages the body. Do not wrench any other part of the Model RFC 30, RFC43, and RFC49 sprinklers are available in <br /> sprinkler/cup assembly. The Model FC wrench is designed to ordinary temperature classification for installation where the <br /> be turned with a standard 1/2"square drive.Tighten the sprin- Maximum Ceiling Temperature does not exceed 100°F(38°C). <br /> kler into the fitting after applying a PTFE based thread sealant Model RFC58 sprinklers are available in either ordinary or in- <br /> to the sprinkler's threads.Recommended installation torque is 8 termediate temperature classification for installation where the <br /> to 18 ft/lb(11 to 24 N/m). Maximum Ceiling Temperature does not exceed 100°F (38°C) <br /> or 150°F(66°C), respectively. <br /> Bulletin 006 Rev.K .t Page 6 of 7 <br /> February 2017 Rellabld www.reliablesprinkler.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.