My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Fire Suppression System
Orono
>
Property Files
>
Street Address
>
M
>
Mooney Lake Drive (Formeraly 300 Sixth Ave N)
>
1180 Mooney Lake Drive - 25-118-23-41-0016
>
Land Use
>
Fire Suppression System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:07 PM
Creation date
1/18/2019 2:18:42 PM
Metadata
Fields
Template:
x Address Old
House Number
1180
Street Name
Mooney Lake
Street Type
Drive
Address
1180 Mooney Lake Drive
Document Type
Land Use
PIN
2511823410016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I 1 <br /> r <br /> ► 5. Maintenance Cover Plate Finishes(1) <br /> Model RFS42 Concealed Sprinklers should be inspected Standard Finish <br /> and maintained in accordance with NFPA 25. Do not clean <br /> sprinklers with soap and water,ammonia or any other clean- White <br /> ing fluids. Remove dust by using a soft brush or gentle Special Application Finishes <br /> vacuuming. Replace any sprinkler or cover plate assem- Flat White Paint <br /> bly, which has been painted (other than factory applied)or Off White Paint <br /> damaged in any way. A stock of spare sprinklers should Black Paint <br /> be maintained to allow quick replacement of damaged or Custom Color Paint <br /> operated sprinklers. Prior to installation, sprinklers should Bright Brass <br /> be maintained in their original cartons and packaging until Bronze <br /> Cme <br /> used to minimize the potential for damage to sprinklers that Satin n <br /> SChrome <br /> Chrome <br /> would cause improper operation or non-operation. Once Black Plating <br /> operated automatic sprinklers and cover plates cannot be <br /> reassembled and reused. New sprinklers of the same size, Other colors and finishes are available. Consult factory for details. <br /> type and temperature rating must be installed. A cabinet of Note: Paint or any other coatings applied over the factory <br /> replacement sprinklers should be provided for this purpose. finish will void all approvals and warranties. <br /> Model RFS42 Residential Flat Cover Concealed <br /> Horizontal Sidewall Sprinkler Specification Ordering Information <br /> Sprinklers shall be a UL listed as residential flat cover Specify: <br /> concealed horizontal sprinkler with RFS42 deflector and 1. Model RFS42 Residential Sidewall <br /> adjustable cover plate for light hazard, interior, non- 2. Cover Plate Type: Solid or Perforated <br /> corrosive applications. Sprinklers to be of bronze frame 3. Cover Plate Finish <br /> construction with brass cover plate and copper alloy <br /> retainer flange assembly.Water seal assembly shall consist Installation Wrench <br /> of a Teflon"coated Belleville spring washer and machined Model G6 Sprinkler Wrench <br /> brass cup containing no plastic parts.Method of attaching <br /> the cover plate to the sprinkler cup shall be a Push-on Installation Aid <br /> and Pull-off design allowing a 1/8" cover plate adjustment. A protective plastic cap is included for use during instal <br /> Sprinklers shall have a nominal K-factor of 4.2(60 metric), <br /> and 1/2" NPT thread. Sprinkler temperature rating shall lation. <br /> be 165°F(74°C) with a cover plate temperature rating of <br /> 135°F (57°C). Sprinklers shall be capable of a maximum <br /> coverage area of 16 ft. x 20 ft. (4.9 m x 6.1 m), with a <br /> minimum lateral spacing of 8 ft. (2.4 m). Rated working <br /> pressure shall be 175 psi (12,0 bar). A plastic protective <br /> cap shall be provided and factory installed onto the <br /> sprinkler cup to protect the sprinkler from damage, which <br /> could occur during construction before the cover plate <br /> is installed. Cover plate type: [Solid] [Perforated]. Cover <br /> plate finish: [White] [Custom Color—specify]. Residential <br /> Coverage Concealed horizontal sidewall sprinklers shall <br /> be Reliable Model RFS42. SIN RA4835(Bulletin 048). <br /> *DuPont Registered Trademark <br /> The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory <br /> Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. <br /> Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly <br /> qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. <br /> Manufactured b <br /> Reliable Automatic Sprinkler Co.,Inc. ® Recycled <br /> ® (800)431-15881-2042 Sales Offices Paper <br /> ' (800)848 6051 Sales Fax Revision lines indicate updated or new data. <br /> (914)829 Corporate Offices <br /> www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.04/15 P/N 9999970457 <br />
The URL can be used to link to this page
Your browser does not support the video tag.