My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SP Testing Inc
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1795 Fox Street - 03-117-23-44-0006
>
Septic
>
SP Testing Inc
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:39:04 PM
Creation date
1/18/2019 1:47:38 PM
Metadata
Fields
Template:
x Address Old
House Number
1795
Street Name
Fox
Street Type
Street
Address
1795 Fox St
Document Type
Septic
PIN
0311723440006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> INSPECTOR CHECKLIST - Multi flow - Pressure bed <br /> Lot 2,Blk.1, Fox Hill Orono <br /> CWELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPERTY LINES setback: 10'to everything <br /> Road setback: platted: 10'prop line. Metes& bounds: out of road easement, or outer ditch. <br /> LAKE/BLUFF setback: 20'for bluff. Lakes: GD_, RD_, NE . Protected wetland <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure sc 10'to bed,tank E sewer line. (else sewer line > 12" below) <br /> ESewer line & baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8'). <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> I Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 1500 gallons trash trap/multi-flow dose tank <br /> Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br /> 750 gallon Multi-flow unit UV light req'd No <br /> Treatment pump 30 gpm 10 head 17.6 gal 35 sec ON 29.4 min OFF <br /> 10 ft 2 inch supply line <br /> C timer ON float 18 inches from bottom HLA at 75%tank capacity <br /> Dispersal: <br /> I I Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfg 1500 gallons <br /> 111 dose pump 47 gpm 24 head VERIFY PUMP CURVE 4.3 min ON 9 hr OFF <br /> U float setting drop 7.0 inches at 29 gpi "DESIGNED" <br /> 203.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected) <br /> LABEL pump requirements and drawdown on riser or panel <br /> I 1 Cam lock reachable from grade- 30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> C2.0 inch supply pipe: sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> Esplice box / control panel / electrical connections <br /> Bed dimensions 15 X 67.0 <br /> Rock depth below pipe 12 inches <br /> Rock bottom elevation 16.0 inches from Grade to bottom of rock(max) <br /> cover depth of 12"+ VERIFY <br /> 5 laterals (1-2'from edge of rock) <br /> 1.50 inch pipe size (sch40 pipe &fittings) <br /> 3.0 ft lateral spacing <br /> 0 3/16 inch perforations (smaller is ok) <br /> n3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold. VERIFY <br /> clean outs (deep bed 2'of head) (no hard 90's) <br /> 4" inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system if necessary Re-use existing tank certification <br /> monitoring plan and type <br /> well abandonment if necessary <br />
The URL can be used to link to this page
Your browser does not support the video tag.