septic info
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
2450 Sixth Ave N - 28-118-23-41-0003
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:49 PM
Creation date
1/18/2019 1:25:04 PM
Metadata
Fields
Template:
x Address Old
House Number
2450
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
2450 6th Avenue North
Document Type
Septic
PIN
2811823410003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office eox 66 <br /> Crystal eay, MN 55323-0066 � � ON–SITE SEWA(�E TREATMENT <br /> INSPECTION REPORT <br /> ti <br /> h <br /> ��9kESII��'�G <br /> Owner: .S�^�E 1/'l� �DLt �Q-� Address: 2 y$v SiX rv1 !�I/��v / �53�b� <br /> r <br /> Permit #�'s: �y�� Dates: I�i�–o�7—�Contractors: �il/idi'Ii�7t �ORDS. <br /> City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is � an existing system [ 7 new construction) <br /> S1'STEM CONFORMITY C1-3): � <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet alt the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface uaters. <br /> 3 "NON-CONPORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic j�has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identifie2J, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> 5 Punpout not needed at this time. <br /> (� Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. <br /> T Solids accunulation in tanks is at a critical level. Yanks should be purtiped out as soon as possible. <br /> 8 System is discharging to the surface. 7anks must be punped out within 48 hours to eliminate surface discharse. <br /> 9 lnspection risers missing-tanks could not be inspected. Inspection risers (4" dia, pipe> must be installed �n each <br /> tank at next pumpout. If tanks have not been punped out within the last three years, they should be p�mped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation>. <br /> If tanks have not been p�mped out within the last three years, they should be punped out now. <br /> DRAINFIELD CONDITION C11-14): � <br /> D�field inspection indicates: <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated efftuent to the surface. Contact the City lnspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Orainfield extent and condition unknown. <br /> LIMITING S1TE FACTORS Cslooe,setbecks.etc.): �– <br /> POTENTIAL FOR SYSTEM FAILURE Cdecends on soils,water table,etc.): <br /> COMMENTS• <br /> � <br /> Dat of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opin�on of the adequacy of the system under current conditions based on the available <br /> informetion. <br /> This report must be kept on the prerises with the system tocetion and p�nnping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.