My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1993-005185 - septic system
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
2300 Sixth Ave N - 27-118-23-32-0002
>
Septic
>
1993-005185 - septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:20:00 PM
Creation date
1/18/2019 12:52:18 PM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
2300 6th Avenue North
Document Type
Septic
PIN
2711823320002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �'F'' TESTING� INC. Steven B. Schirmers = MPCA Cert. No. 627 ; <br /> , <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (612) 497-3566 � <br /> �, � I <br /> � i <br /> �l ; i ; <br /> October 9, 1992 I <br /> , . <br /> Robin 0'Rourke ; ; , ; , <br /> S1/2 - NWl/4 - NW1I4 - SW1/4 ; ; ; + � �+ <br /> Sec.27, T118, R23 I � , ; � <br /> Co.Rd. 6 ' � ' � ' <br /> i i , •, i <br /> i <br /> Orono, Henn. Co. , MN , � ; � ' �, <br /> ; , � . . <br /> • p � <br /> � <br /> This On-Site Sewaqe Treatment Sy�stem is Defi igned for a Type 1, �hre� t �. <br /> bedroom home in accordance with the Minnesota Pollution Control� , f <br /> Agency Chapter 7080 and local ordinances. , i <br /> � <br /> � The soils on this site are SCS aoi.ls ma��pd - T.,+B - i . I <br /> A seasonally high water table was located at 18" to 34" , (mottled ! <br /> soil) . Due to the seasonally high water tabls, a Pressurized� ` � i <br /> Mound System will need to he install�rl. The b�ttom of the roc�c� : � { <br /> bed must be located at least 3 ' above the seas�nally high ' � ' <br /> water table. � I <br /> � <br /> The soils at a de th of 12" have a ( <br /> p percolation rate averaging : , . <br /> 11.4 min/inch and are adequate for treating septic effluent. ; � <br /> • A pumping chamber will need to be installed to lift the effluent to . I : <br /> the treatment area. <br /> � � <br /> The manifold and supply line pipe must have back drainage to the pumping � <br /> chamber. The distribution pipes shall have their ends capped. , Be sure � <br /> the rock and sand fill material are clean. The sod layer below the <br /> entire mounded area must be turned over, just break up the sod, be sure ; <br /> not to over work. • i <br /> I <br /> The power supply and switches must be located outside the manhole and � <br /> pumping chamber in a weather� proof enclosure. A warning device must i <br /> be installed with a light and sound device, this is in case of a pump <br /> failure. Mercury floats are a good method. . � <br /> All neighboring wells are located greater than 100' away from the ! <br /> proposed treatment area. <br /> ; <br /> . � <br /> � � <br /> i <br /> , i <br /> � � <br /> � , , <br /> ; ; <br /> � , . <br /> . CONT'D, . t� � '�' <br /> � i :. ;: <br /> � ; ` ; � . <br /> � �� <br /> � � ; {: <br /> . . � ; ,; <br /> ,� , <br /> .E , � <br /> � <br /> :) � . j , <br /> �� . . , <br />