Laserfiche WebLink
AET Project No. 20-06374 — Page 5 of 8 <br /> We performed compressive strength testing of 1 ] sets of test cylinders cast by AET personnel. <br /> The results of these tests were presented in our Reports of Compressive Strength of Cylindrical <br /> Concrete Specimens. Copies of these were previously submitted under separate cover. The test <br /> results exceeded the specified 28-day design compressive strength. <br /> MASONRY OBSERVATIONS AND TESTING <br /> During construction of the masonry bearing walls, AET personnel made periodic visits to the site <br /> to perform observations. These services were performed on a will-call basis between the dates of <br /> October 9 and November 3, 2006. Our services included the following: <br /> • Observing that the proper units were used, and that the units were clean and dry. <br /> • Observing that the masonry bearing surfaces were clean before the mortar and masonry units <br /> were placed. <br /> • Observing that the spaces to receive the grout were clean before grout corefill was placed. <br /> • Observing the vertical reinforcement, including placement and alignment of bars and dowels, <br /> measuring the bar sizes and lengths of bar lap splices, and observing the clearance between <br /> bars and clearance from masonry units. <br /> • Observing the general construction practices required by the project specifications. <br /> Based on our observations, it appeared that those portions of the masonry wall which we <br /> observed during our visits to the site were being constructed in general conformance with the <br /> approved project plans and specifications. We observed several deficiencies on October 9, 2006 <br /> with the reinforcing steel placement within the masonry wall. The deficiencies observed were <br /> corrected and re-observed the same day. <br /> We also performed compressive strength testing of grout corefil] "prisms" cast during masonry <br /> wall construction observed by AET personnel. The results of these tests were presented in our <br /> Reports of Compressive Strength of Grout Specimens. Copies of these reports were previously <br />