Laserfiche WebLink
` i SEPTIC SYSTEM INVENTOR Y <br /> Address: 2060 Sixth Ave. N. PID: 27-118-23 31 0002 <br /> Building Type church BRs Install'd for: 575 In Musa: Yes <br /> Permit#: 1409 Date of Permit: 11/7/88 Installer: Jerry Johnson <br /> System Type: mound Experimental: no Tank Filter: <br /> SYSTEM CONDITION <br /> Conformity: 1 Tank Condition: 5 DF condition: 11 Failure Pot: low <br /> SEPTIC TANKS <br /> Material: precast concrete Capacity: 1000, 1000, 1000 <br /> Setback to Bldg: 20 Cesspool: no <br /> DRAINFIELD <br /> Length of Lines: 150 # Lines: 3 Trench Width: 10 <br /> Treatment Area: 80*30 Type of Filter: rock,clean sand Soil Boring: yes <br /> Tile Size: 1.5 Under Tile: 9 Perc Rate: 15 <br /> Setback DF-Bldg: 75 DF Ht above Wt: 3 <br /> Soil Type: clay loam Limitations: water table <br /> WELL DATA <br /> Setbacks - Well-Tanks: 90 Well-DF: 75 Report in File yes <br /> Pump Type: subm. Depth: 179 Diameter: 4 Method: drilled <br /> INSPECTION RECORD PUMPOUT RECORD <br /> DA TE DESCRIPTION COMPLIANCE DA TE GALL ONS <br /> 11/18/88 replacement installation 1 9/25/00 2600 <br /> 9/13/90 no surfacing 1 3/11/02 2800 <br /> 5/16/95 no surfacing-pump tanks 1 <br /> 9/23/98 compliant 1 <br /> 9/5/00 no surfacing, pump tanks 1 <br /> 10/08/02 no surfacing code system <br /> f�_ i 2.o�l Q IG <br /> N��j K� �1 5 U � �/ o G ��"'#'�'' � �A''TG Q�o L�� � `� d 7 <br /> � <br /> �` _ � �, <br /> , , <br /> i _ <br />