Laserfiche WebLink
System Speci�cations <br /> Pump Tank: <br /> • A 2.5 inch electrical conduit is to be used for the pump cords <br /> • The piping is to accessible from ground level for future repair <br /> • The supply line leaving the tank is to be sleeved over any <br /> excavated ground in 4" sch 40 PVC and sealed with a 4x2 Fernco <br /> • The floats are to be installed on a float tree <br /> • The pump must be placed on a pump block <br /> • A minimum of a 1/4" drainback hole must be drilled in the supply <br /> line to avoid freezing <br /> Due to the depth of the septic tanks (8' deep) reinforced tanks will be <br /> required <br /> 60' feet of 2" insulated PVC is to be run under the driveway <br /> An "Effluent Filter" is to be installed in the outlet of the second tank. It <br /> should be easily accessible from the ground surface for cleaning. The <br /> effluent filter will be equipped with an alarm. <br /> All run-off water is to be diverted away from the tanks and drainfield <br /> areas <br /> Plastic bolt down manhole covers are to be used and left at grade level <br /> for maintenance access. <br /> Pressure rate glue joint fittings must be used. <br /> If the septic tanks are less than 3' deep the covers are to be insulated <br /> with 2" hi�h-density foam <br /> . . �5--4- � �S � <br /> � � � l� c�a,���� � � � <br /> � �� ��� <br />