Ventilation, Makeup and Combustion Air Calculations . <br /> - . Submittal Form For New Dwellings <br /> Site address ' LAI _fit/ ' L1., 1�. VN-C.) Date 3-�7z_i <br /> Contractor `M�i,' -L �ShAA�'l� / 1-Competed GJ <br /> Section A <br /> Ventilation Quantity <br /> (Determine quantity by using Table N1104.2 or Equation 11-1) . <br /> Square feet(Conditioned area induding <br /> Basement—finished or unfinished) _ ' 51 1 O Total required ventilation Z 620 <br /> Number of bedrooms 5 Continuous ventilation /O ) <br /> Directions-Determine the total and continuous ventilation rate by either using Table N11042 or equation 11-1. <br /> The table and equation are below. <br /> Table N1104.2 - - - <br /> Total and Continuous Ventilation Rates(in cfm) • <br /> Number of Bedrooms - <br /> 1 2 • 3 4 - 5 6 • <br /> Conditioned space(in Total/.. Total/ Total/ Total/ Total/ Total/ <br /> sq.ft.) continuous continuous continuous continuous .continuous continuous <br /> _1000-1500 -60/40 75/40 90/45 105/53 120/60 135/68 <br /> 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 <br /> 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 <br /> 2501-3000 • 90/45 105A3 . 120/60 135/68 150/75 165/83 <br /> 3001-3500 100/50 115/58 - -130/65 145/73 160/80 175/88 <br /> 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 <br /> 4001-4500 _ 120/60 135/68 150/75 165/83. 180/90 195/98 <br /> 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 <br /> 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 <br /> 5501-6000 150/75 165/83. 180/90 , 195/98 210/105 225/113 <br /> Equation 11-1 " <br /> (0.02 x square feet of conditioned space)+(15 x(number of bedrooms+1}]=Total ventilation rate(cfm) <br /> I Conditioned space includes the basement. <br /> 2 If conditioned space exceeds_6000 sq._ t._or there_are more.than 6 bedrooms, use <br /> Egiiatioii 11-1 from-SectionN1104.2 to calculate total ventilation idle_ <br /> Total ventilation-The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, <br /> for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventila- <br /> tors(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor <br /> air intake,or both,for defrost or other equipment cycling. <br /> Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided,on a con- <br /> tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may <br /> have automatic cycling controls providing the average flow rate for each hour is met. <br /> Pagel of 6 <br />