My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1994-006372 - septic system
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
1550 Sixth Ave N - 26-118-23-32-0017/0007
>
Septic
>
1994-006372 - septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:17:18 PM
Creation date
1/14/2019 2:56:00 PM
Metadata
Fields
Template:
x Address Old
House Number
1550
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
1550 6th Avenue North
Document Type
Septic
PIN
2611823320017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . - ti <br /> �"�'' TESTING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (612) 497-3566 <br /> _._ _ _ - <br /> --� <br /> R_... .----- , <br /> � <br /> k, "} <br /> July 13 , 1992 <br /> Jim Lawrence � <br /> 1550 Ca.Rd.#6 <br /> � � 4 ��;�.,,. <br /> existing house, lot 1 �U�- - <br /> Orono, Henn. Co. , MN <br /> This On-Site Sewage Treatment System is Desi.gned for a Type 1, five <br /> bedroom home (4BR home with 1BR guest house) in accordance with <br /> the Minnesota Pollution Control Agency Chapter 7080 and local <br /> ordinances . ( future expansion for the existing house) . <br /> The soils on this site are SCS soils mapped - HbB - Hayden loam. <br /> A seasonally high water table was located at 20" to 26" , (mottled <br /> soil ) . Due to the seasonally high water table, a Pressurized <br /> Mound system will need to be installed. The bottom of the rock <br /> bedmust be located at least 3 ' above the seasonally high water <br /> table. <br /> The soils at a depth of 12" have a percolati.on rate averaging <br /> 8 . 1 min/incti. and are adequate for treating septic effluent. <br /> A pumping chamber will need to be installed to lift the effluent to the <br /> treatment area . <br /> The manifold and supply line pipe must have back drainage to the pumping <br /> chamber. The distribution pipes shall have their ends capped. Be sure <br /> the rock and sand fill material are clean. The sod layer below the <br /> entire mounded area must be turned over, just break up the sod, be sure <br /> not to over work. <br /> The power supply and switches must be located outside the manhole and <br /> pumping chamber in a weather proof enclosure . A warning device must <br /> be installed with a light and sound device, this is in case of a pump <br /> failure . Mercury floats are a good method. <br /> The existing tanks may be used upon approval by the local Inspector. <br /> All neighboring wells are located greater than 100 ' away from the <br /> proposed treatment area . <br /> CONT'D <br />
The URL can be used to link to this page
Your browser does not support the video tag.