Laserfiche WebLink
` ����o ca�� <br /> � <br /> Permit Number <br /> MECcheck Compliance Report <br /> 1999 Minnesota Energy Code <br /> MECcheck Software Version 3.2 Release 1 Checked By/Date <br /> TITLE: Crotteau Remodeling <br /> COLJNTY:Hennepin <br /> STATE:Minnesota <br /> ZONE:2 <br /> CONSTRUCTION TYPE: Single Family <br /> DATE: 08/OS/02 <br /> DATE OF PLANS: 8-6-02 <br /> PROJECT INFORMATION: <br /> Crotteau <br /> COMPANY INF(JRMATION: <br /> Sharratt Design Company Architect <br /> COMPLIANCE:Passes <br /> Maximum UA= 1091 <br /> Your Home=765 <br /> 29.9%Better Than Code <br /> Gross Glazing <br /> Area or Cavity Cont. or poor <br /> Perimeter R-Value R-Value U-Factor UA <br /> Ceiling 1: Raised or Energy Truss 3078 52.0 40.0 34 <br /> Wall 1: Wood Frame,24"o.c. 5694 19.0 15.0 158 <br /> Window 1: Above Grrade,Wood Frame,Double Pane with Low-E 1114 0.310 345 <br /> Door 1: Glass 78 0.360 28 <br /> Basement Wall 1: <br /> Solid Concrete or Masonry, 8.0'ht/2.0'bg/8.0' insul 1359 1 l.0 8.0 56 <br /> Window 2: <br /> Basement>5.6 ft2, Wood Frame,Double Pane with Low-E 218 0310 68 <br /> Basement Wa112: Wood Frame, 8.0'ht/4.5'bg/8.0' insul 198 19.0 12.0 6 <br /> Slab l: Heated,4A'insul. 105 12.0 70 <br /> Furnace 1: Forced Hot Air,90 AFLJE <br /> Air Conditioner 1: Electric Central Air, 13.5 SEER <br /> Proposed and Maximum U-Factor Averages <br /> Proposed Maximum <br /> Average U-Factor Allowed U-Factor <br /> Above-Grade Windows and Glass Doors 0.313 0.370 <br /> Includes Foundation Windows> 5.6 ft2 <br /> COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and ot <br /> Energy Code requirements in MECcheck Version 3.2 Release 1. <br />