Laserfiche WebLink
On tbe North Sbore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT POST OFFICE BOX 66 <br /> � . � � 1335 S. Brown Rd. <br /> Crystal Bay,MN 55323 <br /> � 473-7357 <br /> OWNER Q✓�V � �V7� ADDRESS a� SJ ��1�-'• /'�' <br /> PERMIT NO.'S. � DATES ' CONTRACTORS ` <br /> City Ordinance No.210 requires that ead�on-eite sewage matment system in Orono be inspected on a regular basia.The onsite sewage <br /> treatment system at the above address has been in�ected and eppaan to fall into the category checked below. <br /> (This ia � an exiating sy:tem ❑ new conmuction) <br /> � � Meets or exceeda current City siandards in all respects relating to design,construction,and location.Appean to be operating <br /> PrW���Y. <br /> � 2 Does not meet all current City standards for new construction (1978 Codel but in most respects appears to be designed, <br /> loceted, and constructed generaliy ln accordance with previoua codea.System appears to be functioning properly;no major <br /> upgrading of the system is required at this time. <br /> � 3 Does not meet curre�t City standards in m�y respects relating to desig�,constructio�,or location.Appears to be operating <br /> adequately at this time, but has a relatively high potential for future problema. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City sta�dards for design,construction or location,but is faiiing to property treat and <br /> dispose of the current input,and is endangering a water supply,or is a sour�of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwite creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procxdures. If drainfield replacement is�ecesssry,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is atarted. <br /> SYSTEM CONDITION ( m Checked items may require your ection) <br /> Tank inspection indicatea: ❑ Inapection pipe is loceted directly over tank beffle.(Does not <br /> ❑ Pumpout not needed at this time. give accurate m�ureme�t of solids accumulation.) If tanks <br /> ❑ Solids aecumulation in tanks indicetea they should be pump� have not been pumped out within the la:t three years,they <br /> ed out this year to help prevent future problems. should be pumped out now. <br /> ❑ Soli� accumulation i� tanka ia at a critical level. Tanks Drainfield inspection indicates: <br /> ahould be pumped out aa aon es poseible. �Drainfield is dry,no surfacing evident. <br /> ❑ System ia discharging to surface. Tanka must be pumped ❑ Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. ❑ Dreinfield is saturated and visibly discharging untreated <br /> � ,� Inspection risers misting—tanks could not be inq�ected, effluent to the surface, This condition may require replace- <br /> Inapection risera (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contect the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repeirs muat be completed within 90 days. <br /> the IastJyear�,they shoutd be pumped out now. ❑ Drainfield extent and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil typea,water Future Expansion <br /> O Soil table,and system condition) �Adequate <br /> ❑ High water table �Low ❑ Fair <br /> ❑ Lot size ❑Medium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High . O Inadequate <br /> O Drainage ❑System is causing visible <br /> surface disctiarge. <br /> � � � <br /> COMMENTS: A <br /> '' -9 <br /> �ia-� <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does�ot guarentee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current conditions bssed on the avaitable informatio�. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />