Laserfiche WebLink
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWAQ�E TREATMENT <br /> � � INSPECTION REPORT <br /> �� G~ <br /> 9kESH�4'� <br /> I�� ���� Gr� ` ' ;�v- � <br /> Owner: \ /1�� � Address: ����� St7`�iti �- <br /> Permit #'s: Dates: Contractors: <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site seuage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is DC] an existing system [ ] new construction) <br /> /� <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system uhich meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> Without discharging any pollutants into ground or surface uaters. <br /> 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and Which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging <br /> any pollutants into ground or surface uaters. <br /> 3 "NON-CONfORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and uhich is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> betueen the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic [ 7 has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> � Pumpout not needed at this time. <br /> � 6, Solids accumulation in tanks indicates they should be Pumped out this year to help prevent tuture problems. <br /> � Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be insPected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next purt�out. If tanks have not been p�miped out within the last three years, they should be purtiped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been punped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION C11-14): <br /> D field inspection indicates: <br /> �Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): � <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �4 ��,;� <br /> COMMENTS: G� �,t 1'� l!l � (�n -�i�L� . L-� J-P.r�rt ;�z� � ' �CI��' /.72� <br /> l c;��P iZ- l�t �J /Z— /— fx�2. ' '�Fn tti 5 ;n u sl- /7-<.- u�u �vE � �E�g ics c�,'FG�cr(I cc�u �e2 <br /> V� ✓r . • ( r tfc'c� � µi C; � <br /> v.,------ <br /> Dat of Inspe tion ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the pre�nises with the system loc�ti�n and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />