Laserfiche WebLink
� o�. <br /> o.��,, o <br /> . <br /> ���r� CITY of �RONO <br /> ,� ��j��-� .,��-'�, s,► <br /> � r�';p,����`�;� ti,� biunlcipaI Offices • <br /> �;;z..����. � _ : - <br /> 't �}�.,;�i,` g,'� Street Address: MalilnY Addreu: <br /> ��SI30 2750 Keiley Paricway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> . 95d-�4q-4600 <br /> To Current Owner: Address: ���S S'kt� A�e . N� <br /> Ciry Ordinance 199 requires that each existina on-site sewage treatment system in Orono be inspected every two yean. <br /> The on-site sewa�e treatinent system at the above address has been inspected and appeazs to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-31: 3 <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,daign and conswction standards of the current Orono Munlcipai Code. <br /> 2 "COMPLIANT SYSTEM" An tSTS which dou nat meet all the location.design and construction standards of the current Orono hiunicipal <br /> Code but docs meet the three foot separation rcquirement or two faot requircment for rysums installed 1996 or earlier.and which Is not failing or <br /> -�an imminent threat to public health or safery. <br /> 3O "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a daignated l00-yeu flood plain,any ISTS which may <br /> or may not meet all the tocation,design,or construcGon standards of t�e current Orono Municipal Code and which is failing for any teason;and <br /> any ISTS with less than three feet of unsaturated soil or sand between the d'uaibudon device and the limiting soil characiecistia. <br /> TAMC CONDITION(5:7): � �� <br /> Tank inspection indicates: . <br /> OS Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. <br /> Tank was lazt pumpad 6-�0-01 �. � <br /> l�iake sure sentic tanks are oumaed throngh manhole and not through white inspection oines <br /> This allows for the oroner cleanin�. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. <br /> DRAINFIELD CONDITION -1Q : � <br /> 8 Dninfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet , � <br /> 10 Drainfield is saturated and visibly dischargino untreated effluent to the surface. Contact the Ciry Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> C01ii1�NTS: Or,:���c��, ;s nan- caMp),�,�fi �n� rn�st he tepla�� /,�, �a-3/-2r'�7 . <br /> , <br /> ►d-�-c�a. �a�C <br /> Date of Inspection Matt Bolterman- Sepdc System Inspector <br /> Notr. ln the event that this inspectioa report is used W satisfy the rcquircments for a moctgage or other tra�ufer of properry.be advised that this t+epoR docs not guars.�uc <br /> or certify tliat an existing rystem will continue to tuncdon properly.but is merely an opinion ofthe adequary of the system under current condidons based on the availabie <br /> information. <br />