Laserfiche WebLink
, L <br /> 1 , � Graham Environmental Services, Inc. S1095 Westland Drive <br /> � � Spring Valley, WI 54767 <br /> Phone: 715-778-5730/888-279-2070 <br /> ����' Fax: 715-778-5867/888-279-2069 <br /> Memorandum <br /> TO: Catherine Bach <br /> FROM: Mike Graham�-� � <br /> DATE: June 20, 2012 <br /> SUBJECT: Spring Hill Golf Club Sequencing Application <br /> Catherine, <br /> Since our meeting of June 4, 2012 with yourself and other members of the Technical <br /> Evaluation Panel (TEP), we have completed additional information for the TEP's <br /> consideration of sequencing flexibility(Minn. Rules 8420.0520 Subp. 7a) for the wetland <br /> impacts proposed as part of improvements to the 13�' hole at Spring Hill Golf Club. <br /> Specifically, we have completed MnRAM analyses for the entire wetland complex on the <br /> site (referenced as Wetland 15 in old permit documents), the proposed north impact <br /> site, the proposed south impact site, and the proposed on-site mitigation wetland. The <br /> consultant for the wetland bank proposed to be used for the remaining mitigation <br /> requirement has completed a MnRAM analysis for the wetland bank. <br /> Based upon the MCWD's policy of desiring wetland mitigation within the watershed <br /> district, Spring Hill has proposed to provide what mitigation it can on the site which <br /> would be adjacent to the proposed south wetland fill area. Space within the golf course <br /> is limited and, as this would be a wetland "creation", only up to seventy-five percent of <br /> the new wetland area on the site would be eligible for wetland credit and the required <br /> finrenty-five foot average upland buffer(per WCA) would likely qualify for up to twenty- <br /> five percent credit. For these reasons, Spring Hill proposes to purchase approximately <br /> one-half of the required mitigation credit from a wetland bank (see below). <br /> Revised Wetland Imqact <br /> Since our June 4 meeting, Spring Hill has modified its plans which would reduce the <br /> amount of proposed wetland impact in both the north and south fill areas. In the north <br /> fill area, the proposed earthen bridge has been deleted from the plan and the existing <br /> span bridge will be reconstructed or replaced to address the maintenance and safety <br /> issues discussed in GES, Inc.'s March 30, 2012 Sequencing Application document. <br /> Based on preliminary grading plans, the north wetland fill area would cover 15,568 <br /> square feet (0.36 acres) as opposed to the 20,600 square feet (0.47 acres) originally <br /> proposed. <br /> . . . <br />