Laserfiche WebLink
On the North Sbore o f <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT POST OFFICE BOX 66 <br /> � . � � 1335 S. Brown Rd. <br /> Crystal Bay, MN 55323 <br /> � 473-7357 <br /> OWNER �,��! ir�l�►�I�SOI� ADDRESS ��a� Sl�i/L°Y �t�/� � <br /> PERMIT NO.'S. �19� DATES ��9� CONTRACTORS ��� r���/ �� <br /> City Ordinence No.210 requires that sach on3ite sewage treatmerit system in Orono be inspected on a regular bsais.The o�site sevvage <br /> treatment system at the above address haa been inapected and eppears to fall into the category checked below. <br /> (This ia l� an existing system ❑ new construction) <br /> � � Meets or exceedt current City stsndarda in all respects relating to design,construction,and location.Appeara to be operating <br /> P►���Y. <br /> � 2 Does not meet all current City standerds for new �nstruction (1978 Code) but in most respects appears to be designed, <br /> located, and conatructed generally in accordence with previous codes,System sppears to be functioning properly;no major <br /> upgreding of the system is required at this time. <br /> � 3 Does not meet current City standarda in many respects relating to design,cOnstruction,or locetion.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problema. No major upgrading of system is required at <br /> this time. <br /> � 4 Syatem mey or may not meet current City :tanderds for design,construction or location,but is failing to properly treat and <br /> dispose of the current input,and is endengering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is othervvise creating a public nuisence.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement ia necessary,soil testing will usuelly be required,and a design and site plan <br /> muat be submitted for review.Your contractor must obtain a permit before work is atarted. <br /> SYSTEM CONDITION ( m Checked items may require your action) <br /> Ta�k inapection indicates: ❑ Inapsction pipe is loceted directly over tank beffle.(Doea not <br /> �Pumpout not needed at this time. give accurate m�surement of solida eccumulation.) If tanks <br /> ❑ Solids accumulation in tenks indicetea they ahould be pump- have not been pumped out within the latt three y�ra,they <br /> ed out this year to halp p►event future problems. �ould be pumped out now. <br /> ❑ Solids accumulation in tanka ia at a criticel level. Tanks Drai field i�spection indicetea: <br /> should be pumped out aa aoon ea poasible. � Drainfield is dry,no aurf�ing evident. <br /> ❑ Syatem is diacharging to wrfacx, Tanks must be pumped ❑ Some evidenc�e of surfecing,not critical yet. <br /> wiMin 48 hours to eliminate surfatx ditcharge. ❑ Drainfield is saturated and visibly dischprging untreated <br /> ❑ Inspection riaen miaing—tanks could not be inspected, effluent to the aurfsce. 7his condition mey require replace- <br /> Inspection risen 14"dia.pipe)must be installed in eech tank ment or additiona to �ainfield. Contact the City I�spector <br /> at next pumpout. If tankt have not been pumped out within immediately.Repeirs muat be completed within 90 days. <br /> the last three yeara,they should be pumped out now. ❑ Drainfield extent and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expension <br /> ❑ Soil table,and system condition) �Adequate <br /> O High water table � Low O Fair <br /> ❑ Lot size ❑Medium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High , ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discha�ge. <br /> COMMENTS: <br /> �✓O`V`�1� <br /> Date of I�spection eptic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirementa for a mortgage or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current conditions based on the available informatio�. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />