Laserfiche WebLink
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON-SITE SI:WA(�E TREATMENT <br /> IN3PECTION REPORT <br /> ti <br /> ti <br /> ���k o��G <br /> EsH <br /> Owner:��t91�'I/45 dSl4�-L° `J Address:��97� S��UE� V��� �l2 � <br /> Permit #�'s: S / Datea: � �q��� Contractors: ��D I,�x- l���� ��. <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is � an existing system [ ] neW construction) <br /> STSTEM CONFORMITY C1-3): <br /> 1 �'CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any poltutants �nto gro�d or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or mey not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing tor any reason; and any.system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limitin� soil characteristic [ ] has or [ ] has not been identified at this time. If the limiting soil <br /> characteristtc has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> T� inspection indicates: <br /> (5� Pumpout not needed at this time. <br /> `S Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar$e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. lf tanks have not been pu�ed out within the last three years, they should be Fxnped <br /> out now. <br /> 10 Inspection pipe is located directly over tank beffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been p�mped out within the last three years, they should be punped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> D field inspection indicates: <br /> �1 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repeirs must be completed within 90 days. <br /> 14 Drainfield extent and condition �known. <br /> LIMITING SITE FACTORS (sloce.setbecks,etc.): (,�J�qTE1t-T!4 t- <br /> POTENTIAL fOR SYSTEM fAILURE Cdecends on soils.water table.etc.): !�� — �j/?�Q/�(�� <br /> ( <br /> COMMENTS( � 5 ! ��� �iDr1� S 5 q �i4K/i�� <br /> t <br /> at of Inspection Sep ic System Inspector <br /> Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system witl continue to function <br /> propertyi but is merely an opim on of the adequacy of the system under current conditions besed on the available <br /> informet�on. <br /> This report must be kept on the pre:nises with the system locstion and pumping records. <br /> WHITE COPY/Inspecto►s File YELLOW COPY/Homeowne� <br />