Laserfiche WebLink
�°� <br /> o , o <br /> -�'-�,���� � CITY of ORONO <br /> ����. �� <br /> �,� .:_ �+ <br /> . � ti M���� ot��� <br /> P�;��I�. Q � <br /> \ ,t .,�����`ti�'° G Street Address: Mailin�Addross: <br /> r'��F$�1` .¢,'�V <br /> '��xQ 2150 Keiley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: ����Q_ �j ..�� Address: 2675 Silver View Dr. <br /> Permit #'s: 2057 Dates: 6/29/69 Contractors: Clover Aill Co. <br /> (This is [�] an existing system [ ] new construction) . <br /> ✓ - <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> �3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [ ] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION l5-91 : 5 ' <br /> ,�5 �Pumpout not needed at this time. <br /> �6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ ] mater tight or the condition is [ ] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to ev sion.) <br /> DRAINFIELD CONDITION (11-14) : 12 <br /> � Drainfield is dry, no surfacing evident. <br /> 1 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : high <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic <br /> system is required by 12/31/2009. <br /> /��� ---� <br /> Da e of Inspection Se ic System Inspec or <br /> Dlote: In the event that this inspection report is used to satisfy the requirements for a <br /> �ransfer of property, this report does not guarantee that an existing system will continue to <br /> inction properly, but indicates the operation of the system under current conditions. <br /> Telephone(612)249-4600 • Fax(612)249-4616 <br />