Laserfiche WebLink
On the Nortb Shore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> � � � Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER �� � �11..��,� ADDRESS -�� „lYP� ✓ <br /> PERMITNO.'S. /�/3 DATES �� 7 � CONTRACTORSyI ���✓��►"` �e� <br /> City Ordinanoe No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage <br /> treatment system at the above address has been inapected and appean to fall into the category checked below. <br /> (This is � an existing systern ❑ new conatruction) <br /> � � Meets or exceeds current City atandards in all respects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> � 2 Does not meet all current City stsndards fo� new construction (1978 Code) but in most respects appears to be designed, <br /> located, and constructed generally in accorda�ce with previous codes.System appears to be fu�ctioning properly;no major <br /> upgreding of the system is required at this time. <br /> � 3 Does not meet current City standerds in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time,but has a relatively high potentiat for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and <br /> dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is othervvise creati�g a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replaceme�t is necessary,soil testit�g will ususlly be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION ( m Checked items mey require your action) <br /> Tank inspection indicates: ❑ Inapection pipe is loceted directly over tank baffle.(Does not <br /> .�Pumpout not needed at this time. give eccurate m�surement of solids sccumulation.) If tanks <br /> ❑ Solids a�xumulation in tanks indicetes they should be pump� have not been pumped out within the I�t three years,they <br /> ed out this year to help prevent future problema. should be pumped out now. <br /> ❑ Solida accumulation in tanks ia at a critical level. Tanks �rai field i�spection indicates: <br /> should be pumped out as soon as possible. �� Drainfield is dry,no surfacing evident. <br /> ❑ System is diacharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. O Drainfield is saturated and visibly discharging untreated <br /> ❑ Inspection risen miasing—tanks could not be inspected, effluent to the surface. This condition may requi�e replace- <br /> I�spection risera (4"dia.pipe)must be instelled in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed withi�90 days." <br /> the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown, <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for � <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> O Soil table and system condition) �Adequate <br /> ❑ High water table �Low O Fair <br /> � Lot size ❑ Medium �Poor <br /> ❑ Lake,wetland,or stream ❑ High ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discharge. <br /> COMMENTS: � � � <br /> i i <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the aystem under curre�t conditio�s based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />