Laserfiche WebLink
�°� <br /> ��o 0 <br /> ��{� � ��� <br /> -� :�� CITY of _ __ _ �1T0 <br /> ' a��l <br /> i � �� r�*� � <br /> �� � f�`.��3 � � Municipal Ot'fices <br /> � "�`'✓'�,�'w 4 a� G <br /> 'Str��i AYYr�ss: MaiUn�Addrass: <br /> ���KQ�'w 2150 Kelley Parkway P.O, Box 66 <br /> -- Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> I <br /> Owner: Address: 330 Silver Meadow Dr. <br /> Permit #'s: 1477 Dates: 11/23/88 Contractors: Patnode Bros. j <br /> (This is [� an existinq system ( ] new construction) . <br /> ,SySTEM COMPLIANCE (1-3) : 1 <br /> 1 Code System: Meets or exceeds current City standards in all respects relatinq to design, i <br /> construction, and location. Appears to be operating properly. i <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in ' <br /> most respects appears to be designed, located, and constructed in accordance with previous � <br /> codes and is functioning properly. , <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, ; <br /> construction, or location, but is failing to properly treat ar.d dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of � <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [�] or is not [ ] identified under this septic syatem. If the , <br /> saturated soil level is not identified, thia classification is subject to revision.) <br /> K CONDITION (5-9) : 5 <br /> 5 Pumpout not needed at this time. � <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. � <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. � <br /> 9 Inspection pipe is located 'over tank baffle-can not measure solids accumulation. If tanks ' <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. ' <br /> (The tanks are [ ] or are not [ ] water tight or the condition is [�] unknown. If the tanks <br /> are not con£irmed to be watertight, this classificstion is aubject to ie�sion.) <br /> INFIELD CONDITION (11-14) : 11 i <br /> 1 Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact � <br /> the City Inspector immediately. Repair must be completed within 90 days. � <br /> 14 Drainfield extent and condition unknown. � <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low <br /> CONIl�IENTS: In order to confirm that your septic system meets Minnesota standards, soil borings �, <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 3 feet and the system is compliant. <br /> -�-q� <br /> Date of Inspection ep ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy • the requirements for a <br /> transfer of property, this report does not guarantee that an existinq system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone(612)249-4600 • Fax(612)249-4616 <br />