My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: weather station tower
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3880 Shoreline Drive - 17-117-23-33-0151
>
Correspondence
>
Re: weather station tower
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:37:08 PM
Creation date
1/2/2019 10:21:59 AM
Metadata
Fields
Template:
x Address Old
House Number
3880
Street Name
Shoreline
Street Type
Drive
Address
3880 Shoreline Drive
Document Type
Correspondence
PIN
1711723330151
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�d..+�t�Y�°�i'��.d <br /> , Hennepin County <br /> AET Project No. 09-00552 <br /> July 7, 2017 <br /> Page 4 of 4 <br /> Preparation of the tower base subgrade should involve removal of any vegetation and any <br /> organic soil with over 3 percent organic content by weight from within the tower base area and a <br /> minimum 3-foot oversize area. Additional excavation should be completed as necessary to allow <br /> placement of a minimum of 6 inches of Class 2 aggregate base. <br /> Prior to placement of the aggregate base, the exposed subgrade should be surface-compacted <br /> with a minimum of four passes with a vibratory compactor having a minirnum dynamic force of <br /> 15,000 pounds. The aggregate base should then be placed and compacted to a firm, non-yielding <br /> condition. <br /> Procedures <br /> The hand auger boring was drilled with a 1'/2-inch diameter hand auger. The borings were <br /> advanced in 4- to 6-inch increments to depth of 9.5 feet below the ground surface. The auger was <br /> withdrawn from the borehole after each advancement to obtain soil cuttings. <br /> The dynamic cone penetrometer (DCP) tests were completed in general accordance with ASTM <br /> International Standard Test Method D6951. <br /> Remarks <br /> It has been a pleasure assisting you with this project. Please contact us if you have any questions <br /> regarding our results or this report. <br /> Sincerely, <br /> American Engineering esting, Inc. <br /> . ��� <br /> Daniel J. Larso P Loren Braun, PE <br /> Principal Enginee Principal Engineer <br /> MN Lic. No. 19649 <br /> Phone: 651-659-1337 <br /> dlarson@amengtest.com <br /> Attachments: Subsurface Boring Logs <br /> Photograph of In Situ Load Test Set Up <br />
The URL can be used to link to this page
Your browser does not support the video tag.