My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: weather station tower
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3880 Shoreline Drive - 17-117-23-33-0151
>
Correspondence
>
Re: weather station tower
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:37:08 PM
Creation date
1/2/2019 10:21:59 AM
Metadata
Fields
Template:
x Address Old
House Number
3880
Street Name
Shoreline
Street Type
Drive
Address
3880 Shoreline Drive
Document Type
Correspondence
PIN
1711723330151
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, �������� <br /> Hennepin County <br /> AET Project No. OS-06764 <br /> May 24, 2016 <br /> Page 3 of 5 <br /> • Adult Correctional Facilitv <br /> The soil boring encountered fill that extended to a depth of approximately 6 %z feet. The <br /> fill consisted mostly of lean clay with gravel to a depth of 2 '/2 feet then lean clay with <br /> sand to a depth of 5 feet, sandy lean clay with a trace of gravel to a depth of 6 feet and <br /> clayey sand to a depth of approximately 6 'h feet. The boring terminated at a depth of 7 <br /> feet in sand that was fine to medium grained. It was not possible to determine if the sand <br /> was natural soil or fill. <br /> Helical Anchor Analysis <br /> We completed a dynamic cone penetrometer (DCP) test at a depth of 6 feet in each of the <br /> borings. Based on a correlation to DCP blows, we estimated the standard penetration resistance <br /> (N-value) at the DCP locations. Using the estimated N-value, we determined the uplift resistance <br /> of the soil with installation of a 4-inch diameter helical anchor. Our analysis indicates that <br /> adequate capacity is available to resist pullout from a 990-pound force from the guy wires. Our <br /> analysis includes a minimum factor of safety of two. <br /> The test location at the Adult Correctional Facility encountered uncontrolled fill. Uncontrolled <br /> fill is fill that appears to have been placed without regard to consistency or compaction effort. <br /> Consequently, inadequate bearing capacity may occur at some of the anchor locations because of <br /> the variability in the condition of the fill. As a result, deeper embedment of the anchors may be <br /> required at this site. The capacity of the anchor will need to be verified at the time of placement <br /> by measuring the torque required to install it. <br /> Deadman Anchor Anal.� <br /> We understand that concrete deadman anchors may be utilized at some of the towers. The size <br /> and installation of the deadmen is specified in the Campbell Instruction Manual. For a deadman <br /> anchor buried with compacted backfill and its top at grade (i.e. no soil overburden on the <br /> anchor), we recommend assuming the resistance to uplift is equal to the weight of the concrete in <br /> the anchor. Backfill around the deadman anchor should be compacted to a minimum of 95 <br /> percent of its maximum dry density based on the standard Proctor test (ASTM International, <br /> Specification D698). <br /> For wind uplift, which is a transient load, we recommend using a minimum factor of safety of <br /> 1.5 for the ratio between the calculated uplift resistance and the design uplift loads. For a 2'x 2' <br /> x 2' deadman (as specified in the Campbell Instruction Manual), the weight would be <br /> approximately 1,200 pounds which is 1.2 times the design uplift load. To achieve a 1.5 factor of <br /> safety, a minimum 27" x 27" x 27" deadman should be used. <br /> Frost Heave <br /> The soils present on the five sites have a moderate to high frost heave potential. If lenses of silt <br /> are present within the soil profile, about 1 to 3 inches of frost heave may occur. Frost penetration <br /> in clay soils would be approximately 4 feet during an average winter, and 5 feet during a severe <br /> winter. Comparable frost penetration for sand soils would be about 6 feet during an average <br /> winter, and 7 feet during a severe winter. These frost penetration depths assume there is no snow <br /> cover providing insulation to the underlying ground. <br />
The URL can be used to link to this page
Your browser does not support the video tag.