My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00936 - alarm system
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3542 Shoreline Drive - 17-117-23-43-0113
>
Permits/Inspections
>
2017-00936 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:42:49 PM
Creation date
12/12/2018 11:46:16 AM
Metadata
Fields
Template:
x Address Old
House Number
3542
Street Name
Shoreline
Street Type
Drive
Address
3542 Shoreline Drive
Document Type
Permits/Inspections
PIN
1711723430113
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SPECIFICATIONS <br /> System Capacity condensing) at 32°C ±2°C (90°F t 3°F). However, the useful <br /> life of the system's standby batteries and the electronic compo- <br /> • Intelligent Signalling Line Circuits.........................................1 nents may be adversely affected by extreme temperature ranges <br /> • Addressable device capacity..............................................50 and humidity. Therefore,it is recommended that this system and <br /> • Programmable software zones...........................................20 its peripherals be installed in an environment with a normal room <br /> • Annunciators.........................................................................8 temperature of 15—27°C/60—80°F. <br /> Electrical Specifications NFPA Standards <br /> AC Power: MS-9050UD 120 VAC,60 Hz,3.0 A.MS-9050UDE: The MS-9050UD(E) complies with the following NFPA 72 Fire <br /> 240 VAC,50 Hz, 1.5 A.Wire size:minimum 14 AWG(2.00 mm2) Alarm Systems requirements: <br /> with 600 V insulation.Nonpower-limited,supervised. —LOCAL (Automatic, Manual, Waterflow and Sprinkler <br /> Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Supervisory). <br /> Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two —AUXILIARY (Automatic, Manual and Waterflow) (requires <br /> 18 AH batteries.) 4XTMF). <br /> Communication Loop: Supervised and power-limited. —REMOTE STATION (Automatic, Manual and Waterflow) <br /> (Where a DACT is not accepted, the alarm, trouble and <br /> Notification Appliance Circuits: Terminal Block provides con- supervisory relays may be connected to UL 864 listed <br /> nections for two NACs, Style Y (Class B) or Style Z(Class A). transmitters. For reverse polarity signaling of alarm and <br /> Special Application power. Power-limited, supervised circuitry. trouble,4XTMF is required.) <br /> Maximum signaling current per circuit:2.5 A.End-of-Line Resis- _pROPR1ETARY(Automatic,Manual and Waterflow). <br /> tor:4.7k ohm,'/z watt(P/N 71252 UL listed)for Style Y(Class B) <br /> NAC. Refer to the Fire•Lite Device Compatibility Document for —CENTRAL STATION (Automatic, Manual and Waterflow, <br /> listed compatible devices. and Sprinkler Supervised). <br /> Two Programmable Relays and One Fixed Trouble Relay: —OT,PSDN(Other Technologies,Packet-switched Data Net- <br /> Contact rating: 2.0 A (�3 30 VDC (resistive), 0.5 A � 30 VAC Work) <br /> (resistive). Form-C relays,nonpower-limited,nonsupervised. <br /> Agency Listings and Approvals <br /> Cabinet Specifications The listings and approvals below apply to the basic MS- <br /> Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.72" 9050UD(E) control panel. In some cases, certain modules may <br /> (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" not be listed by certain approval agencies, or listing may be in <br /> (42.29 cm.)wide x 5.25" (13.34 cm.)deep.Trim Ring(TR-CE): Process.Consult factory for latest listing status. <br /> =- 22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • UL:S624 <br /> • FM approved <br /> Shipping Specifications • CSFM:7165-0075:210 <br /> Weight: 26.9 Ibs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • MEA:442-06-E <br /> high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. NOTE:See DF-60445 for ULC-listed model. <br /> Temperature and Humidity Ranges <br /> This system meets NFPA requirements for operation at 0 — <br /> 49°C/32—120°F and at a relative humidity 93%t 2%RH(non- <br /> FireLite� Alarms� and System Sensor� are registered trademarks oi <br /> Honeywell International Inc. MicrosoflC� and Windows� are registered <br /> trademarks of the Microsoft Corporation. <br /> 002012 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> of this document is strictly prohibited. <br /> '�O 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. �� <br /> EN6INEERIN6 8 MANIIFACNAIN6 All specifications are subject to change without notice. � <br /> QUALITY SYSiEMS MadeintheU.S.A. <br /> For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. <br /> www.firelite.com <br /> Page 4 of 4—DF-52418:E1•1/27/12 <br />