Laserfiche WebLink
' <br /> ' <br /> SpectrAlert Advance Specifications <br /> , General <br /> SpectrAlert Advance strobes and hom strobes shall mount to a standard 4 x 4 x 1 Yrinch back box,4-inch octagon back box,or double- <br /> gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17B-inch back box.A universal mounting plate shall be used for <br /> ' mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert <br /> Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit <br /> output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit <br /> outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 <br /> , volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified <br /> unfiltered power supply.Strobes and hom strobes shall have field-selectable candela settings including 15, 15/75,3Q 75,95, 110, 115, 135, <br /> 150, 177,and 185. <br /> ' Strobe <br /> The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. <br /> The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for <br /> visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash <br /> ' tube and associated lens/reflector system. <br /> Horn Strobe Combination <br /> The hom strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for <br /> fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with <br /> ' Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light <br /> shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch <br /> between a temporal three pattem and a non-temporal(continuous)pattem.These options are set by a multiple position switch.On four-wire <br /> products,the strobe shall be powered independently of the sounder.The hom on hom strobe models shall operate on a coded or non-coded <br /> , power supply. <br /> Synchronization Module <br /> The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module <br /> ' shall synchronize SpectrAlert strobes at 1 Hz and homs at temporal three.Also,while operating the strobes,the module shall silence the homs <br /> on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also <br /> control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more <br /> synchronization modules together wiil synchronize all the zones they control.The module shall not operate on a coded power supply. <br /> , . . - . .• . . <br /> Standard Operating Temperature 32°F to 120°F(0°C to 49°C) <br /> Humidity Range 10 to 93%non-condensing <br /> ' Strobe Flash Rate 1 flash per second <br /> Nominai Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' <br /> Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) <br /> Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) <br /> ' InputTerminal Wire Gauge 12 to 18 AWG <br /> Ceiling-Mount Dimensions(including lens) 6.8"diameter x 25'high(173 mm diameter x 64 mm high) <br /> Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) <br /> (SBBCR,SBBCW) <br /> ' Notes: <br /> 1.Full Wave Rectified(FWR)voltage is a non-regulated.time-varymg power source that is used on some power supply and panel outputs. <br /> 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. <br /> ' <br /> 1 <br /> ' <br /> , <br /> avos��r,-o� <br /> , <br />