Laserfiche WebLink
DENSITY TESTS OF COMPACTED FILL <br /> PROJECT NAME: ADDN.-RICK'S SUPER VALU PROJECT NO: 4122 92-1014 <br /> NAVARRE, MN PAGE: � 6 <br /> TEST NUMBER: 54 <br /> DATE TAKEN: 10-16-91 <br /> IJNIFIED SOIL CLASSIFICATION: Sandy lean clay, <br /> (Moisture-Density Sample Number) brown (CL)-3 <br /> LOCATION: Plumbing trench, <br /> 23'E & 45'S of <br /> NW corner of addn. <br /> (Retest of #51) <br /> DEPTH BELOW FLOOR GRADE: 1.5' <br /> DEPTH BELOW EXISTING GRADE: 6" <br /> FIELD DENSITY DETERMINATION: <br /> Method Nuclear Density Method B, ASTM:D2922-81 (-#4 Basis) <br /> Dry Density (pc� 120.5 <br /> Moisture Content (%) 9.0 <br /> Plus #4 Material (%) 5 <br /> LABORATORY MOISTURE-DENSITY RELATION OF SOIL: <br /> Method ASTM:D1557-78, Method "A", (-#4 Basis) <br /> Maximum Dry Density (pc� 122.7 <br /> Optimum Moisture (%) 12.4 <br /> COMPACTION TEST RESULTS: <br /> Compaction (%) 98 <br /> Specified Compaction (%) 95 <br /> ATTENTION: Density tests are valid at the location and elevation of the test only. No representation is made <br /> as to the adequacy of fill and compaction at locations and elevations other than those tested. <br /> The tests were performed by Chad Birch. <br /> AS A MUTUAL PROTECTION TO CLIENTS,THE PUBLIC AND OURSELVES.ALL TWIN CITY TESTING CORPORATION REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS, <br /> AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTIONS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR PRIOR WRITTEN APPROVAL. <br />