Laserfiche WebLink
• � .�._,....J <br /> I ROOF DC Roof Special 1 7 <br /> li I _�__ �� (Job Reference(op6onaD <br /> Litifin Truss Company,VNnsted,MN,. �� 8.730 s Oct 26 2017 MiTek Indushies,Inc. Mon Dec 4 13:17�02 2017 Page 1 <br /> I D:_kBXcgo3MnH4xt 6zeXAhpwyQACX-fVd8sP7E?H8sUaeFn7HGrPHwOfjMYaGOhPnmkqCKnF <br /> 5-7-7 10-10-14 16-2-5 23-7-7 26�-12 <br /> 5-7-7 53-7 5-3-7 7-52 2-9-5 <br /> 4x8 I I Scale=1:46.6 <br /> REPAIR: <br /> � STUB RIGHT END 4-9-10 3 <br /> 7.0o iz <br /> 14 15 <br /> i LSx4 \\ �3 �s 1.5 // <br /> 2 4 ��O <br /> � p q� 16"X 32" 2_�_� <br /> ol �� <br /> ml i z <br /> �i <br /> i 4n9 // 5 <br /> 1 <br /> � - <br /> o �. <br /> .- . <br /> � <br /> r ,� <br /> N <br /> :�_ ' v <br /> i �--y--� <br /> _ ..__-._-_. . __.._.. ._ . .._ .__.... ...... _...__ ....1 Y 1 . _.. .___ _.._...._. a t <br /> O <br /> 9 8 � <br /> 10 g <br /> sxa I I axiz - 3�s= GUSSET MAY BE TRIMMED <br /> sxe = TIGHT TO SINGLE PLY HANGER <br /> CUT WEB JUST BEYOND CONNECTOR PLATES AT ITS END. <br /> THE JOINT MUST REMAIN UNDISTURBED. <br /> '.,�I ATTACH 1/2"PLYWOOD OR OSB GUSSET(15132"RATED SHEATHING 32/16 EXP 1) <br /> �_ ` INSTALL 2 X 4 SPF/DF/SP N0.2 ���t J TO EACH FACE OF TRUSS WITH(0.131"X 2.5"MIN.)NAILS PER THE FOLLOWING NAIL SCHEDULE: <br /> CUT TO FIT TIGHT. -�' 2 X 3'S-2 ROWS,2 X 4'S-3 ROWS,2 X 6'S AND LARGER-4 ROWS:SPACED @ 4"O.C. <br /> NAILS TO BE DRIVEN FROM BOTH FACES.STAGGER SPACING FROM FRONT TO BACK FACE <br /> FOR A NET 2"O.C.SPACING IN EACH COVERED TRUSS MEMBER.USE 2"MEMBER END DISTANCE. <br /> i 7-0-5 149-7 _�_ 23-7-7 26-4-12 , <br /> i ____ <br /> -_-__ 26-4-12 <br /> Plate Offsets(X,l�_ f 1 0-4-4 0-1 2 <br /> �_o-z-iz.az-oj �a:a2-so-ai2L----- __ _ --- - <br /> _____ __-- -___. __ _ ___ _- - -- -- -- __. <br /> - _---- - <br /> LOADING(ps� SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP <br /> TCLL 38.5 plate Grip DOL 1.15 TC 0.67 Vert(LL) -0.05 9-70 >999 240 MT20 197/144 <br /> (Ground Snow=50.0) Lumber DOL 1.15 BC 0.42 Vert(TL) -0.14 7-9 >999 180 <br /> TCDL 15.0 Rep Stress Incr YES WB 0.69 Horz(TL) 0.02 6 n/a n/a <br /> BCLL 0.0 Code IBC2012lTPI2007 Matrix-MSH Weight:126 Ib FT=20% <br /> BCDL 10.0 <br /> LUMBER- BRACING- <br /> TOP CHORD 2x4 DF No.2 or 2x4 DF-N No.t/No2'Except' TOP CHORD Structural wood sheathing directly applied or 4-4-9 oc purlins, except <br /> 3-5:2x4 SP 2850F 2.3E end verticals. <br /> BOT CHORD 2x4 DF No2 or 2x4 DF-N No.1/No2'Except' BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br /> 6-8:2x4 DF 1800F 1.6E WEBS 1 Row at midpt 4-6 <br /> WEBS 2u3 SPF Stud'ExcepY MiTek recommends that Stabitizers and required cross bracing <br /> 3-9,3-7,7-11:2x4 DF Std or 2x4 SPF Stud, :2u4 DF 1800F 1.6E be installed during truss erection,in accordance with Stabilizer <br /> 1-10,5-6:2x4 DF No.2 or 2x4 DF-N No.1INo.2,46:2x4 SPF No.2 Installation guide. <br /> REACTIONS. (Ib/size) 10=1356/Mechanical,6=1356/Mechanical <br /> Max Horz 10=221(LC 13) <br /> Max UpIift10=-86(LC 14),6=-86(LC 14) <br /> FORCES. (Ib)-Mau.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. <br /> TOP CHORD 1-2=-1490/156,2-3=-1344/233,3-4=-1327/232,1-10=-1292/154,5�=-281/91 <br /> BOT CHORD 7-9=-44/862,6-7=-103/1056 <br /> WEBS 1-9=-81/1154,2-9=-639/176,3-9=-72/474,3-7=-71/449,4-7=-268/162,4-6=-1420/108 I Hereb certi that this lan, <br /> NOTES- (10-12) y fy p speci• <br /> 1)Wind:ASCE 7-10;VuIt=115mph(3-second gust)Vasd=9lmph;TCDL=6.Opsf;BCDL=6.Opsf;h=25ft;8=45ft;L=26ft;eave=4ft;Cat.II; ficatan,or report was prepared by <br /> Exp C;enclosed;MWFRS(directional)and C-C Euterior(2)0-1-12 to 3-1-12,Interior(1)3-1-12 to 10-1Q14,Exterior(2)10-10-14 to me or under my direct supervision <br /> 13-10-14 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for and that I am a duly Licensed Pro- <br /> readions shown;Lumber DOL=1.60 plate grip DOL=1.60 fes,iona eer under e laws <br /> 2)TCLL:ASCE 7-10;Pg=50.0 psf(ground snow);Pf=38.5 psf(flat roof snow);Category II;Exp C;Partially Exp.;Ct=1.1 of th fate ot Minn a. <br /> 3)Unbalanced snow loads have been considered for this design. <br /> 4)Provide adequate drainage to prevent water ponding. <br /> 5)N/A <br /> STEVEN E.FOX <br /> 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 7)Refer to girder(s)for truss to truss connections. <br /> 8)Provide mechanicat connection(by others)of truss to bearing plate capable of withstanding 86 Ib uplift atjoint 10 and 86 Ib uplift atjoint <br /> g. DATE REG.NO.21980 <br /> 9)N/A <br /> 10)This truss must not be exposed to environments that are corrosive or greater than 19 percent moisture,and moisture of lumber not to December 4,2��7 <br /> 11) is the responsibility of the engineer of record to determine the suitabili�y of this component for this pro ect per ANSI/TPI 1 Sedion 2. �� <br /> WARNING-Verly design psrameters antl READ NOTES ON THIS AND INCLUDED MIIEK REFERENCE PAGE MII-7473 rev.�0/03/Y015 BEFORE USE`. �� <br /> Design valid for use only vnth MiTek�connectors.This design is based only upon parameters shown,and is tor an individual building component,not <br /> a truss system.Before use,the building designer must venfy the applicabiliry of design parameters and propedy incorporate Mis desiqn into the overall <br /> building design. Bracing Indfcated is to prevent buckling of individual wss v✓eb and/or chord members only. Additional temporary and permanent bracing M iTe k <br /> is always required for stability and to prevent collapse with possible personal injury and property Aamage. For general guidance regarding the <br />