Laserfiche WebLink
_-o`�� � <br /> � . � <br /> : o o��, <br /> Y � '��'` CITY of ORONO <br /> �� � },� �v. <br /> ,� ,;,, , r�,.. �, : . � <br /> v�,, �;� ;�y. ;;; ,. �lS� Municipal Offices � <br /> '� ;;'±'� ;, '�� <br /> � `;' '+`<`��.``} �' Street Address: �15a-a4q—ybo � Mailing Address: <br /> '9kEgKp4'� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystai Bay, MN 55323-0066 <br /> To Current Owner: Address: �U S� S �`�r t�i�n�: �� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY 1-3 : � <br /> 1 "CODE SYS`TEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the tocation,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requiremcnt for systems installed 1996 or eulier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�ards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chuacteristics. <br /> � <br /> TANK CONDITION(5-71: 5 <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped a i`1-r�3 ). <br /> Make sure septic tanks are pumped throush manhole and not through white inspection pipes. This allows for the proper <br /> cleanin¢. Keep water softner and iron filter dischar¢e out of septic svstem to prolon¢life of drainfield. Ask aumper to test <br /> alarm float to verifv alarm is still workine in vour house. The alarm warns owner that seatase is about to backua into basement. <br /> 7 Inspection risers missing-tanlcs could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> r�._� �-��� a-- S t �-.z. ���5 �o o�C 0 �� <br /> COMMENTS: UJ �- � I <br /> ��'Zq—b Ll u �,,�-, <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Not�: In the event that this inspection report is used to satisf} the requirements for a mortgage or other transfer oFpropcm. be advised that this repur�does <br /> IWl ��U:lCAl1l2G OI' Cl'f11r\' tll8l an e�is'�in2 s�•stem ���ill continue tu f�unction properl�•. but is mereh� an opinion of the adequac}� oF the s��stem un�ler currrni <br /> wn�itiuns based on the avail161c inConnation. <br />