Laserfiche WebLink
=0 '�. . <br /> �' . 1V' <br /> ;; O O`�,,. <br /> �� Y � . CITY of ORONO <br /> ,,.>,:r;�.�, � <br /> ,�1 ,',', . ,._;: �+ � . <br /> ,� � 1� r;,� ,' ��, ': Municipal Offices <br /> �,� �., _ t;`;�G Street Address: q5a-a4q-y6o O Mailing Address: <br /> '9x��p'4�' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �� �b `��6�'t �.�� o�' <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYST'EM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requ'uement or rivo foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ,�'11'd�-- ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes This allows for the aroper <br /> cleaning Keep water softner and iron filter dischar¢e out of septic svstem to prolons life of drainfield. Ask aumner to test <br /> alarm float to verifv alarm is still workine in vour house The alarm warns owner that septa¢e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be instailed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DR.AINFIELD CONDITION 8-10 : � <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. � <br /> 10 Drainfield is saturated and visibly discharging untreated eftluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �f`�:r�(-;-e�U � po�-� 6k _ 1 v� S(p ���- '�.�1�C� <br /> ��l�--�-.-�r ZU D�, <br /> �-L"�-�'� ��`'�� G <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Notc: In the e��ent that this inspection report is used to satistj�the requirements for a mortgage or other transfer of prop�rt�. be ad��ised that this report does <br /> nut �uaranlee or certih that an e.�isting system ��'ill continue to function properl}•. but is mereh an opinion of tlie adequac� of the s}scem uneler cw�reni <br /> cun�itiuns based on the avail�blc inl'onnation. <br />