Laserfiche WebLink
Mr. Maurice J. Wagener <br /> Pro�ect No. 890831 .202 _. <br /> September 22, 1989 � <br /> Page 4 <br /> Minnesota Geoloaical Survev ' <br /> Well logs at the Mlnnesota Geolo91ca1 Survey (MGS) were revlewed to determine <br /> 1f the three wells on the property are listed. These three wells are not <br /> 1lsted. It 1s recommended that these wells be recorded xfth MGS. <br /> The well at Smlths Bay Marina is not currently 1n use. If the aell ts not to <br /> be used 1t should be properly closed. Well closure procedures must be done 1n <br /> accordance with Minnesota Well Construction Code 4725 by a licensed water well <br /> f1rm. <br /> Minnesota Pollution Control Aaen4Y (MPCA) - Pro�erty Transfer File Evaluation <br /> The MPCA was requested to conduct a limited file search to determine if the <br /> area within an approprlate one-mile radlus of the property contalned any sltes <br /> with known hazardous substances. To date. we have not recelved their <br /> response. When we recelve the MPCA lnformatton. we will lssue the flndings 1n <br /> an addendum to this report. <br /> Undergrou�d Storage Tank (UST) <br /> On-Site <br /> The MPCA was contacted to determine 1f there are any UST recorded for the <br /> referenced propertles. The MPCA stated that there are no UST registered to <br /> 1950, 1955. or 1960 Shoreline Drive. However. on our site visit, a UST was <br /> observed at Smlths Bay Marina. Thts tank is a 3.000 gallon gasoline UST and <br /> was installed approxlmately six years ago. Thts tank needs to be registered <br /> with the MPCA. A UST notification form is enclosed as Attachment A. In May <br /> of 1988 this tank was tested to determine if it was leaking by Determan <br /> Welding. The results of this testing are included in Attachment B. The <br /> results shoa that the tank passed the tank tightness test. As of January <br /> 1989, the Federal EPA approved regulations regarding existing UST. These <br /> regulations are summarized in Attachment C. These regulations require leak <br /> detection by December of 1993 and sp111 overfill protectio� and corrosion <br /> protection by December of 1998 provided this tank was lnstalled after 1980. <br /> The City of Orono Nas contacted regarding the former gas station. The city <br /> representative stated that three tanks xere removed 1n the summer of 1987. <br /> All three UST contained gasoline. At the time of removal approximately <br /> 150-200 gallons of gasoline were spilled from o�e tank. This occurred because <br /> the tank was not emptied prior to removal . According to the C1ty of Orono the � <br /> spill was properly removed. NoNever� these UST are not registered xith the <br /> MPCA. The MPCA reco�nend completing a notification form for each tank <br /> indicating that the tank has been removed. <br /> 9ff-S1tg <br /> Information on leaking UST in the area w111 be lncluded wlth the MPCA <br /> information. <br />