My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
1930 Shoreline Drive - 10-117-23-42-0005
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:27:40 PM
Creation date
11/16/2018 11:11:02 AM
Metadata
Fields
Template:
x Address Old
House Number
1930
Street Name
Shoreline
Street Type
Drive
Address
1930 Shoreline Drive
Document Type
Septic
PIN
1011723420005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO �O� <br /> M�icipal Offices O O <br /> Post Office Box 66 <br /> Crystal eay, MN 55323-0066 � � ON–SITE SEWA(�E TREATl�I�1T <br /> INSPECTION REPORT <br /> ti <br /> H <br /> '�,� G <br /> 9k'ESHOg'� <br /> Owner: _1��� .�—/ I�.Y'� Address: / /JL7 ��/�C J )� <br /> Permit #�'s: /�i Dates: '— Contractore: /.�7lCl1ak.1^� <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is �an existing system [ ] new construction) <br /> STSTEM CONFORMITI' (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING S�STEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> eny pollutants into ground or surface waters. <br /> "NON-CONFORMING STSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which mey or mey not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and an s ' 3 feet of �saturated soil o and <br /> between the distribution device and the timiti oi c aracteristics. <br /> � � _t ��j'�yj 1�3 9�6• <br /> (The limitin soil characteristic f77�has or [ ] has not been identified t this ti If t e limitin soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION CS-10): <br /> Tank inspection indicates: <br /> 5 Punpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be puriped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. 'fanks should be punped out as soon as possible. <br /> System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface discharye. <br /> Inspection risers missing-tanks could not be inspected. Ins ' ' �� ' ' stalted in each <br /> �ank at next cxmpout. If ta have not been out wit in t e last three years, t ey s ou <br /> ou� now. <br /> 10 Inspecti pion pe is lxeted directly over tank beffle (does not give accurate measurement of solids accunulation). <br /> tf tanks have not been p�mped out within the last three years, they should be puiped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> Dpe�field inspection indicates: <br /> (1�/ Drainfield is dry, no surfacing evident. <br /> 't2 Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is seturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be campleted within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slooe,setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (decends on soils,water table.etc J: 1��� <br /> � <br /> COMMENTS: � <br /> • (�,Y� <br /> i <br /> Date of Znspection e ic System Inspector <br /> Note: In the event that this i�nspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or cert�fy that an existing system will continue to f�mction <br /> properly� but is merely en opim on ot the adequacy of the system under current conditions based on the available <br /> informet�on. <br /> This report must be kept on the premises with the system location and punping records. <br /> WHITE COPY/Inspectora File YELLOW COPY/Homeowner <br />