My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01337 - septic
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
1760 Shoreline Drive - 10-117-23-14-0017 (Guest House)
>
Septic
>
2017-01337 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:19:41 PM
Creation date
11/14/2018 11:29:07 AM
Metadata
Fields
Template:
x Address Old
House Number
1760
Street Name
Shoreline
Street Type
Drive
Address
1760 Shoreline Drive
Document Type
Septic
PIN
1011723140017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Insta�ler Summary <br /> 2250 gallon Septic tank(minimum) Tank options: none <br /> wx�arger �anK witn rnu�up�e compi t,anKs <br /> 1300 gallon Dose tank (minimum) at 25.49 gpi <br /> 36 GPM @ 15 ft. of head, Pump required <br /> 7.6 inch swing on Demand float which translates to roughly 4.8 inches of float tether length <br /> if time dosing is requi�ed--> 5.4 minutes ON time& �hours OFF time <br /> 20 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"ftoat <br /> 23 inches from bottom of tank to"Hi Level Alarm"or 33 inches to"Hi level alarm'if time dosed <br /> 30 ft. of 2.0 inch supply line with end feed manifold connection <br /> (Tip: "top feed"manifold to control drainback) <br /> 12 inch, or 1.0 ft. Sand Lfft Mound <br /> 10.0 ft. wide by 63.0 ft. long Rock bed <br /> 3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing <br /> 7/32 inch perts 3.0 ft. perforation spacing <br /> No Effluent filter&atarm <br /> 3 clean out&valve box assemblies <br /> 15.0 ft.Totat sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br /> 5.0 ft. Downslope Isand beyond rockbed, minimum) <br /> Specific slope ratios give BERM widths(topsoil beyond rockbed)of: <br /> 4:1 upslope ratio 8 ft. upslope berm <br /> 3:1 sidestope 13 ft. sideslope berms <br /> 3:1 downslope 23 ft. downslope berm <br /> 4"inspection pipe <br /> 18" cover on top <br /> U slo berm � po�� �� 23 <br /> 12" covee o� sides <br /> {6"bemy cap�c 6"toproiu <br /> 1.0 Clean sand lift <br /> , 2_0 Depth ta Limitin� <br /> ��mitingCond�tion — �----__ ______ <br /> tion Width 15.0 —__�`—_ __—___--__ <br /> Note: <br /> For 0 to 1�slopes, ,4bsorptlan WYdth is measured from the Bedequatly in both direttions. <br /> For slopes >1%, ,�sarptfon Wfdth is meawred downhill fram the upstope ec�e of the Brd <br /> Rock Bed: 21.0 Yd3 or`1.4= 29 ton 6 inches under pipe <br /> Mound Sand: 183 yd3 or•1.4= 256 ton calculation based on 3:1/4:1 stope from top of rockbe� <br /> Loamy Cap: 70 yd3 or•1.4= 98 ton 6"deep <br /> Topsoil: 82 yd3 or"1.4= 115 ton 6"deep <br />