Laserfiche WebLink
��o-�� � <br /> � . � <br /> , o � <br /> o�,, <br /> ��� ; r;.:r:� . CITY of ORONO <br /> � ,��� : .��� � <br /> ,� '�! �. �'��. � ,.' �C, . Municipal Offices <br /> ,� ';;:'t:•.. ; ;,, , '� <br /> ' ` 't�`�` G Street Address: �15a'd�{q—y6� O <br /> �;�. +',; .�,.,� Mailing Address: <br /> �'9$Eggp4'�' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ���� S���e.�'�(�' �(�'- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. , <br /> SYSTEM CONFORMITY (1-3): � <br /> � "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the Locadon,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stanc�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than tluee feet of unsaturated soil or sand beriveen the distribution device and the limiting soil chazacteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> � Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped throueh manhole and not throu¢h white inspection pipes. This allows for the proper <br /> cleanine. Keep water softner and iron flter dischar¢e out of septic svstem to arolons life of drainfield. Ask aumaer to test <br /> alarm float to verifv alarm is still workine in vour house. The alarm warns owner that seatage is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION(8-10): <br /> 8 Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: I��a��e �ll� �UD� ��_ �'J,, Sc��.,C �n�C� <br /> �� l�(C C �/(�� \�Taf S� <br /> ���U—U tJ " r"��v'� •— <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> vot�: In tlie event that tllis inspection repon is used ro satisf� the requirements for a mortgage or otlier transfer oF properh, be advised that this repurl dues <br /> nut ��uarantc�c or eertif� that an e�isting system ��•ill continue to 1Lnclion properl��. hut is merel� an opinion of the adequac� of the s��stem wuler currcnt <br /> �un�itiun,based on the a��ailable inCormation. <br />