Laserfiche WebLink
' ' RIGHT-J LOAD AND EQUIPMENT SUMMARY <br /> • � 1-6-98 <br /> For: DZURIK CONSTRUCTION COMPANY <br /> 5208 Lake Sarah Hts. Dr. <br /> Loretto MN 55357 <br /> 479-1645 <br /> By: CONWAY MECHANICAL <br /> 37498 Hastings St. N.E. <br /> Stanchfield MN 55080 <br /> 689-9181 <br /> Job #: KEIRNAN RESIDENCE <br /> Wthr : Minneapolis/St._Paul AP MN <br /> Zone : <br /> WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS <br /> Outside db: -16 Deg F Outside db: 90 Deg F <br /> Inside db: 70 Deg F Inside db: 72 Deg F <br /> Design TD: 86 Deg F Design TD: 18 Deg F <br /> Daily Range M <br /> Rel . Hum. : 50 % <br /> Grains Water 33 gr <br /> HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING <br /> Bldg. Heat Loss 167483 Btuh Structure 110411 Btuh <br /> Ventilation Air 300 CFM Ventilation 3960 Btuh <br /> Vent Air Loss 28380 Btuh Design Temp. Swing 3.0 Deg F <br /> Design Heat Load 195863 Btuh Use Mfg. Data n <br /> Rate/Swing Mult. 0. 95 <br /> Total Sens Equip Load 108652 Btuh <br /> INFILTRATION LATENT COOLING EQUIP LOAD SIZING <br /> Const Qual b # Fireplaces 3 Internal Gains 2070 Btuh <br /> Ventilation 4488 Btuh <br /> HEATING COOLING Infiltration 5739 Btuh <br /> Area ( sq. ft. ) 8265 8265 Tot Latent Equip Load 12297 Btuh <br /> Volume (cu. ft. ) 76573 76573 <br /> Air Chanqes/Hour 0. 6 0. 2 Total Equip Load 120949 Btuh <br /> Equivalent CFM 767 256 <br /> HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY <br /> Make 2-BRYANT Make � - JANITROL <br /> Model 350MAV0601200 Model CK-60-1 <br /> Type Sealed comb. nat. gas Type Split system elec. Ac. <br /> Efficiency / HSPE 92 . 0 COP/EER/SEER 10.0 <br /> Heating Input 240000 Btuh Sensible Cooling 0 Btuh <br /> Heating Output 223200 Btuh Latent Cooling 0 Btuh <br /> Heating Temp Rise 63 Deg F Total Cooling �a o°A0 Btuh <br /> Actual Heating Fan 3200 CFM Actual Cooling Fan 4000 CFM <br /> Htg Air Flow Factor 0. 019 CFM/Btuh Clg Air Flow Factor 0.036 CFM/Btuh <br /> Space Thermostat Load Sens Heat Ratio 93 <br /> MANUAL J: 7th Ed. RIGHT-J: V1 . 67 TR1524 <br /> Printout certified by ACCA to meet all requirements of Manual Form J <br />