My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-P07119 - new structure
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
1489 Shoreline Drive - 11-117-23-23-0009
>
Permits/Inspections
>
2004-P07119 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:28:43 PM
Creation date
11/8/2018 1:10:17 PM
Metadata
Fields
Template:
x Address Old
House Number
1489
Street Name
Shoreline
Street Type
Drive
Address
1489 Shoreline Drive
Document Type
Permits/Inspections
PIN
1111723230009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jul� Sile /ldcicess: 14�� 7��_ov� � i� �`��+'� _ _ <br /> t <br /> �' ������ ������"CAT�GOI�.Y 1" AL7,ERNAT� I�OR <br /> - OI�IE � TWO rAMILY DWELLINGS <br /> 1NS'TRUC'I'IONS: 1'1►is altcrnalive n�ay �e used for one- and t«�o-family d�vcllings built to �ncel tlic Category 1 rcyuirements of <br /> �Iinnesota Rules, Chapter 7G70. Complete Parts A, B, and C. Clearly mark plans willi: insulation R-values; window and skylight U- <br /> :alues; size and type of equipment; equipment controls; and location of vapor retarder and windwash barriers. More detailed <br /> ;nforn�ation can be found in lhe Afiruiesota Energy Code sununary slieets available from the Minnesota Department of Commerce. <br /> Part A. BUILDING ENVELOPE <br /> ., . ._ . ._., . _ . _ . __ . . . .... . . . <br /> Check proposed envelope joint sealing option -� ❑ Prescriptive(caulking,gaskets,etc.) 0 Performance(test per 7670.0470 subp. 7.C.) <br /> Check thermal energy calculation option used -� ❑ "Cookbook" (complete worksheet below) j� MnCheck method(attach report) <br /> ❑ Performance (attacli U-value calculations) ❑ Systems Analysis melfiod (attach analysis) <br /> ��Cookbook�� W�1-ksheet MINI111UNt REQUIREMENTS <br /> Cor"Cookbook"o tion ool <br /> ❑ Ceiling lnsulation: Minimum R-38 with 7'h"energy heel; or <br /> INSTRUCTIONS Minimum R-44 with low truss heel; or <br /> itep I. Check item(s)that design meets on Minimwrt Requiremen�s list Minimum R-38 with R-5 sheathin when no attic. <br /> to the righl. Must meet all items to use"Cookbook"option. ❑ Entry Doors: Max. U-value of 0.30 or 1'/."solid wood with storm <br /> �tep 2. Indicate proposed wall type on table below. ❑ Rim Joist Insulation: Minimum R-19 <br /> �tep 3. Indicate Window U-value and source. ❑ Floors over unconditioned s aces: Minimum R-24 <br /> �tep 4. Verify total window(including area of all foundation windows) ❑ Foundation Insulation: Minimum R-10 <br /> and door area is equal or less than allowable percentage. ❑ Foundation windows: %"insulated lass,wood or vinvl frartie <br /> TABLE FOR DETERM1NtNG MAXI�IU�i�i'IIYDOW AND DOOR AREA <br /> �laximum Allowable Total Window and Door Area as <br /> i Percenta e of Ex osed Wall 12% 14% 16% 18% 20% 22% 24% 26% 28% <br /> Nall T e Standard Framin : Maximum Avera e Window U-value exce t Coundation windows : <br /> J 2x4,R-13 insulation,2 R-7 sheathing 0.55 0.47 0.41 0.36 0.33 0.30 O.Z7 0.25 0.23 <br /> � 2x4,R-15 insulation,2 R-5 sheathing 0.52 0.45 0.39 0.35 0.31 0.28 0.26 0.24 0.22 <br /> � 2x6,R-19 insulation,<R-5 sheathin 0.48 0.41 0.36 0.32 0.29 0.2G 0.24 0.22 0.21 <br /> � 2x6,R-19 insulation,2 R-5 sheathing 0.56 0.48 0.42 0.37 0.34 0.31 0.28 0.26 0.24 <br /> � 2x6,R-21 insulation <R-5 sheathin 0.51 0.43 0.38 0.34 0.30 0.28 0.25 0.23 0.22 <br /> > 2x6,R-ZI insulation,2 R-5 sheathing 0.58 0.50 0.44 0.39 0.35 0.32 0.29 0.27 0.25 <br /> r1'all T e Advanced Framin : Maximum Avera e Window U-value exce t foundation windows : <br /> � 2x6,R-19 insulation,<R-5 sheathin 0.52 0.45 0.39 0.35 0.3 I 0.28 0.26 0.24 0.22 <br /> � 2x6,R-19 insulation, Z R-5 sheathing 0.58 O.SO 0.44 0.39 0.35 0.32 0.29 0.27 0.25 <br /> � 2x6,R-21 insulation,<R-5 sheathin 0.55 0.47 0.41 0.36 033 0.30 0.27 0.25 0.23 <br /> ] 2x6,R-21 insulation,2 R-5 sheatfiing 0.G0 O.S2 0.46 0.41 0.36 0.33 0.30 0.28 0.26 <br /> Window U-value: � Source: O NFRC ❑ ASHRAE 1993 Handbook <br /> 100x -- � � _ ° < ° <br /> window&door area gross exposed wall area DESIGN ALLOWABLE (Gom table above) <br /> MINNESOTA ENERGY CODE - WHICH RULES MAY l USE ? <br /> TYPE OF RESIDENTIAL BUILDING AI'PLICAI3LE RULES <br /> Detact�ed R-3 occupancy 1-and 2-family dwellings Chapter 7672; or <br /> Exam les: sin le famil twin homes du lexes Cha ter 7670"Cate o 1" with statuto de ressurization and ventilation re uirements <br /> Attached R-3 occupancy dwellings Chapter 7G74; or <br /> Exam les: tri lex townhouses and row houses Cha ter 7670 with either"Cate o I" or "Cate o 2" rovisions <br /> R-1 occupaocy bulldfogs of 3 stories or less Cf�apter 7674; or <br /> Exam les: condominiums or a artments Cha ter 7G7U with either"Ca�e or I" or "Cate or 2" rovisions <br /> R-I occupancy bulldings over 3 stories hfgh Chapter 767G <br /> Exam les: hi h rise condos or a ar�ments ���� <br />
The URL can be used to link to this page
Your browser does not support the video tag.